79
ICP0531 Encoder Back-up Battery Pack
IMS-MN-LMDA42C_A.pdf
LMD CANopen
Connector Configuration
J1-J8: Encoder Backup Voltage
To connect encoder battery backup power to a single Absolute MDrive product, use
development cable PD02-0531-FL1 (shown below).
3.3 ft
(1.0m)
+
VBAT+
VBAT-
-
MFG
Housing P/N
Crimp Pin P/N
Crimp Pin Qty
AMP
280358-0
182206-2
2 ea
Pin#
Signal
Description
Wire color
1(+)
V BAT +
Battery positive supply to one (1) LMD Absolute encoder
product
Red
2(–)
V BAT -
Battery negative (return)
Black
J7 Supply and Monitoring
To connect the 24 VDC system supply and optional low-level warning output, use development
cable PD04-0531-FL1 (shown below)
3.3 ft
(1.0m)
+24VDC
GND
GND
LLW (PLC)
1
2
3
4
MFG
Housing P/N
Crimp Pin P/N
Crimp Pin Qty
AMP
280359-0
182206-2
4 ea
Pin#
Signal
Description
Wire Color
1
+VDC
+24 VDC Supply Voltage
Red
2
Low Level
Low Level Voltage Warning output
White
3
GND
+24 VDC return
Black
4
GND
+24 VDC return
Black