21
Certifications
IMS-MN-LMDA42C_A.pdf
LMD CANopen
Certifications
Certification
Regulation #
RoHS
2011/65/EU, 2015/863
EMC
2004/108/EC
REACH
EC 1907/2006
UL
UL 1004-1, UL 1004-3
CSA C22.2 No. 100
CSA C22.2 No. 77
A current list of certifications and compliance information can be viewed at:
https://novantaims.com/dloads/certificationssustainability/
Environmental Conditions
Ambient Operating Conditions
The maximum permissible ambient temperature during operation depends on the distance
between the devices and the required power. Observe the pertinent instructions referenced in
The following relative humidity is permissible during operation.
Operating temperature
1
[°C (°F)]
-20 ... 50 (-4 ... 122) (no icing)
Temperature variation
[°C (°F) min]
0.5 (32.9)
Humidity
[%]
5 ... 95 (non-condensing)
1
If the product is to be used in compliance with UL 508C, note the information provided in “Conditions for UL 508C” on page 15.
Storage and Transport
The environment during transport and storage must be dry and free from dust. The maximum
vibration and shock load must be within the specified limits.
Temperature
[°C (°F)]
-25 ... 70 (-13 ... 158)
Temperature variation
[°C (°F) min]
-25 ... 30 (-13 ... 86)
Humidity
[%]
5 ... 95 (non-condensing)
Temperature Maximums
Power stage
1
[°C (°F)]
85 (185)
Motor
2
[°C (°F)]
100 (212)
1
May be read via
parameter.
2
Measured on the surface of the motor laminations.
Installation Altitude
The installation altitude is defined as height above sea level
Installation altitude
1
[ft (m)]
3280 (1000)
1
Installation above 3280 (1000) may require derating output current and maximum ambient temperature.
Vibration and Shock
Vibration, sinusoidal
m/s
2
10
IEC 60721-3-2
Shock, non-sinusoidal
m/s
2
100
IEC 60721-3-2