Preparing for Configuration
LMD CANopen
CAUTION
HOT SURFACES
• Avoid unprotected contact with hot surfaces.
• Do not allow flammable or heat-sensitive parts in the immediate vicinity of hot surfaces.
• Verify that the heat dissipation is sufficient by performing a test run under maximum load
conditions.
• Check the temperature during test runs.
Failure to follow these instructions can result in injury or equipment damage.
Preparing for Configuration
The following tests are required before configuration:
• The device may be commissioned in system or out of system.
• Only supply voltage
VDC
and the Service interface connections are required for
configuration.
• Ensure that this chapter is read in it’s entirety, as many setup parameters are mode-specific.
For configuration and programming, a computer with the LSS or equivalent Layer Setting
Services master is required.
NOTE:
Detailed usage instructions and screen captures of the LSS are found in the LSS manual,
which is available for download from:
https://novantaims.com/dloads/
Installing the LSS
NOTE:
The CANopen Configuration Utility is the only vehicle for performing firmware upgrades.
• Computer running Windows 7 or greater.
• The MD-CC502-000 or equivalent PEAK/Phytec dongle required to use the CANopen
configuration GUI.
• Reference the LSS product manual for installation and configuration information.
Configuration via Layer Setting Services
The LMD CANopen may be commissioned using Layer Setting Services. Reference the
CANopen Fieldbus Manual and CiA DS-305 for more information.