23
Mounting (Rotary and External Linear Actuators)
IMS-MN-LMDA42C_A.pdf
LMD CANopen
Mounting (Rotary and External Linear Actuators)
Mounting the LMDXA42XC uses four (4) M3 x 0.5 screws on a bolt circle diameter (BCD) of
1.725” (43.81 mm). The length of the screws will be determined by the thickness of the mounting
material plus a maximum of 0.140” (3.56 mm) into the motor housing.
The maximum tightening torque of the screws is 7.8 lb-in (9 kg-cm). The following graphic
shows the rotary and linear actuator mounting hole pattern.
�
1.220
(
�
30.99)
Pilot diameter
Ø 0.866 (22.00)
Ø 1.725 (43.81)
0.118 (3.00) Thru 4 Places
on a 1.725 (43.81) Circle
Mounting (Electric Cylinder with Flange Mount)
The electric cylinder LMD products flange mount option uses front and rear flange plates to
mount the cylinder into the system. The following graphic shows the mounting hole dimensions
for the flanges.
Electric Cylinder Flange Mount (Motor End)
Electric Cylinder Flange Mount (Rod End)
0.250
(6.35 mm)
Side View
Front View
1.890 (48.00 mm)
1.280 ±0.020 (32.50 mm ±0.50)
0.945 (24.00 mm) REF
0.640
(16.25 mm) REF
4 x Ø 0.197
(5.00 mm)
Center axis
of rod
0.188
(4.78 mm)
Side View
Front View
2.500 ± 0.015 (63.50 mm ± 0.38)
2.125 (53.98 mm)
1.670 ±0.015
(42.42 mm ±0.38)
1.220
(30.99 mm)
1.06
(26.92 mm) REF
1.250
(31.75 mm) REF
4 x Ø 0.217
(5.51 mm)
0.61
(15.49 mm)
0.835
(21.21 mm)
Center axis
of rod