Document 52002 VGM NION Instruction Manual Rev. A 09/11/02
2. Click
Change...
to modify the current plug-in
for the selected device. This will access a file selection
dialog showing the Plugin directory. Select the
VGM.cfg
file and click
OK
.
3. The commands associated with the selected configuration file will now appear in the
Choose Icon Menus
display. These are the commands that can now be assigned to a macro function using the
Macro Editor
,
or assigned to a
Functional Button
on the
Floor Plan Display
. These options will automatically appear
on the pulldown menu for the selected device (provided the current workstation has control of the device).
Clicking on an available command will cause the
Device Type for Chosen Menu
display to show what devices
are affected by the chosen command. Some commands will affect all device types, others will have specific types
only. When creating devices to use plug-in commands be sure they are defined as one of the appropriate types.
When the plug-in has been configured, click
OK
to close the
Plug-In Selection and Configuration Form
.
2.4 Mapping Plug-ins With NIONs
In order for plug-in applications to function, they must be linked with the nodes or devices to which they corre-
spond. In most cases this is done automatically, and each recognized node is linked to the appropriate plug-in
application.
There may be times when nodes and devices are not automatically read and updated by the workstation, and links
are not established. Therefore, it is advised that this one-time linking process be checked when assigning new
plug-ins, and if the device type has not been automatically assigned, then assign it manually. This can be done in
the Network Configuration Window. This window is opened by selecting
Tools, Network Administration
.
Node
Site
Device
Unassigned
NION Type
Identified
NION Type
Figure 2-4: Network Configuration Window
NOTE: NIONs are often configured through plug-ins. These configuration tools can only be accessed
from the device pop-up menus. Therefore, before any configuration of the NION can be done, a
device must be created for the node.
To obtain information about a specific node, single click on the desired node,
then select
Edit
,
Inquire NION Type From Node
, and the NION type will
automatically be displayed. Add Node/Delete Node will add or delete a node
from the list displayed in the window. Select Exit when finished.
www.PDF-Zoo.com
firealarmresources.com
Содержание VGM NION UniNet 2000
Страница 2: ...2 Document 52002 VGM NION Instruction Manual Rev A 09 11 02 www PDF Zoo com firealarmresources com...
Страница 14: ...14 Document 52002 VGM NION Instruction Manual Rev A 09 11 02 NOTES www PDF Zoo com firealarmresources com...
Страница 27: ...27 Document 52002 VGM NION Instruction Manual Rev A 09 11 02 NOTES www PDF Zoo com firealarmresources com...