60
S
ECTION
15
Message
Descrip
Ɵ
on
Cause
Solu
Ɵ
on
REPAIR COMMUNICATION
Communica on failure is seen
by the primary unit
Primary and Secondary “x” are
too far apart
Primary and Secondary “x” do
not have line of sight
Primary and Secondary “x”
lost communica on due to
temporary loss of line of sight,
i.e. slow moving transport
truck between signals
Radio channel is changed on
one signal only
Radio dip switches have been
changed
Radio cable is not a ached to
the transmi or
Radio cable has been dam-
aged
Radio interferance
Move machines closer or use
hardwired connec on
Move machines to achieve
line of sight or use hardwired
connec on
Increase drop out me (see
Sec on 6.4)
Enable COMMUNICATION
REGAIN (see 6.4)
Change other signal(s) to
same radio channel
Set the dip switches as per
diagram (see Sec on 12.1)
A ach radio cable to radio
transmi or
Replace radio cable
Change radio channel on all
signals up or down one
channel. Ensure all singals are
changed to the same channel
PROBLEM DETECTED ON
LAMP: X REPAIR MACHINE
Current overload (short
circuit) or underload (open
circuit) lamp outputs
Faulty wire connec on
Faulty wires
Faulty lamp
Faulty controller
Check connec ons and recon-
nect wiring
Check wires, replace where
necessary
Replace faulty lamp
Replace faulty controller
MALFUNCTION RESPONSE
REPAIR MACHINE
Undiagnosed MMU fault
Call 877-352-4626
Call 877-352-4626
ATTENTION: SEE PRIMARY
UNIT
Secondary sees a problem
with the Primary unit
Problem with Primary signal
Go to Primary signal to view
error
ATTENTION: SEE SECONDARY
UNIT “x”
Primary sees a problem with
Secondary unit “x”
Problem with Secondary “x”
signal
Go to Secondary “x” signal to
view error
DEFAULT FLASH RED
Default
fl
ashing, as shown on
Secondary machine
Previous fault has cleared
automa cally
Machine Failure
Press “START” bu on on
Primary when ready to start
program
See Primary unit for instruc-
on
DEFAULT FLASH RED PRESS
START TO RESUME
Default
fl
ashing, as shown on
Primary machine
Previous fault has cleared
automa cally
Machine Failure
Press “START” bu on on
Primary when ready to start
program
See Primary unit for instruc-
on