27
S
ECTION
7
7
S
U W
Z
When setting up a work zone, one unit must be set as the Primary Unit, and all others set as Secondary
units. All Secondary Units should be powered on
fi
rst. Edit the WORK ZONE SETUP and OPTIONS menu
settings as shown below on the Primary and Secondary controllers; starting with the Secondary Units.
Note: When using multiple secondary units, they must always be in numerical order within the network.
(i.e. SEC 1, SEC 2, SEC 3, etc.)
Secondary Setup
1. Proceed to a secondary unit and turn the power on.
2. Select WORK ZONE SETUP.
3. Select UNIT ID and proceed to change the unit ID to the required Secondary ID.
4. Select RADIO CHANNEL and select the desired channel number.
Note: All units to be networked must be on the same RADIO CHANNEL.
Hardwired connection can be selected (requires additional hardware and wiring)
5. Press the BACK button to return to the HOME screen.
6. Repeat steps 3 to 5 for each secondary unit.
7. Proceed to primary unit to continue setup.
Primary Setup
1. Proceed to Primary unit.
a. Select WORK ZONE SETUP.
b. Set the UNIT ID to Primary.
c. Choose the RADIO CHANNEL that was chosen on the secondary units.
d. Select the LAYOUT based on your work zone. Refer to S
ECTION
7.1 L
AYOUTS
(B
ASIC
M
ODE
) for a detailed
list of all available layouts.
e. Select TIMING.
i. Edit Unit (Phase) timing; RED CLEAR, YELLOW, GREEN (MAX and MIN when actuation is
enabled).
ii. Select ACTUATION SETTINGS (if vehicle detection is used).
OPERATOR SHALL BE FULLY TRAINED
OPERATOR SHALL BE
OPTIONS
FEB/01/17 09:53AM
PROGRAM: MODEL V##
HOME
BATTERY:
24.0 VOLTS
UNIT:
SECONDARY 1
RADIO CHANNEL:
03
RADIO SIGNAL:
DEFAULT FLASH RED
PRESS START TO RESUME
LIGHT POSTS
WORK ZONE SETUP
HELP
PRI
SEC1
PHZ
FEB/01/17 09:53AM
PROGRAM: MODEL V##
HOME
>
WZ SETUP
BATTERY:
24.0 VOLTS
UNIT:
SECONDARY 1
RADIO CHANNEL:
03
RADIO SIGNAL:
DEFAULT FLASH RED
PRESS START TO RESUME
UNIT ID
RADIO CHANNEL
SECONDARY 1
03