47
S
ECTION
10
10.2
S
S
D
Using the
and
directional buttons from
the HOME screen will allow you to view the PHASE
STATUS and DIAGNOSTIC screens for each unit in
the network. Press ENTER to view the selected tab.
Diagnostic Screen:
FEB/01/17 09:53AM
PROGRAM: MODEL V##
HOME
>
DIAGNOSTIC
BATTERY:
24.0 VOLTS
UNIT:
PRIMARY
RADIO CHANNEL:
03
RADIO SIGNAL:
DEFAULT FLASH RED
PRESS START TO RESUME
PRI
SEC1
PHZ
MALFUNCTION MANAGEMENT SYSTEM
SECONDARY 1 DIAGNOSTIC
RED
YELLOW
GREEN
24.3V
CONFLICT
NO LAMP
TIMING
VOLTS
LINK
PRE-EMPT QUEUE
ACTIVATION QUEUE
CHECKED ITEMS ARE OK
Status of Lamps – graphic displays the active lamp.
Basic Unit Diagnostic:
• Battery voltage
• Activation Queue: checked if vehicle detection event is
present
• Pre-empt Queue: checked if preemption event is present
MALFUNCTION MANAGEMENT SYSTEM
– the MMS runs
through its systems checks and the checked items con
fi
rm
there are no issues.
Phase Status:
CURRENT PHASE
– displays which unit(s) is being served
by the current phase.
TIME
– indicates how many seconds are remaining for the
corresponding signal indication.
NEXT PHASE
– indicates which unit will be served by the
following phase.
PHASES IN QUEUE
– displays which units will be served
following the unit listed in “NEXT PHASE”.
10.3
S
I
/E
Software updates and preprogrammed traf
fi
c plans can be imported via USB
fl
ash drive. Exporting can be
used to save plans or for transfer of plans to other controllers. This will save all program settings to the
USB
fl
ash drive.
1. From the OPTIONS menu, select SOFTWARE IMPORT/EXPORT. Following the prompt on screen, insert
the USB
fl
ash drive.
2. Select START IMPORT or START EXPORT when ready.
3. Prompt to enter the system passcode will appear. Enter the passcode (see S
ECTION
5.3 S
YSTEM
P
ASSCODE
).
4. Pop-up status window will appear and notify when the export/import in complete.
5. Remove the USB
fl
ash drive.
OPTIONS
HELP
PRI
SEC1
PHZ
FEB/01/17 09:53AM
PROGRAM: MODEL V##
HOME
>
PHZ STATUS
BATTERY:
24.0 VOLTS
UNIT:
PRIMARY
RADIO CHANNEL:
03
RADIO SIGNAL:
DEFAULT FLASH RED
PRESS START TO RESUME
PRI
SEC1
PHZ
CURRENT PHASE
PHASE STATUS
TIME
NEXT PHASE
PHASES IN QUEUE
PRIMARY
3 SECONDS
PRI, SEC 1
SECONDARY 1