13
MM272 Installation Instructions
Connect Opener Power Cables
Step 1
Bring FIRST power cable into the control box through a strain relief slot,
leaving enough wire to reach the FIRST OPR. terminal block.
Insert the individual power cable wires into appropriate terminals on the FIRST
OPR. terminal block (white to WHT; green to GRN; red to RED; black to BLK).
Tighten the set screws. A dab of petroleum jelly on each terminal will help
prevent corrosion.
Step 2
Pull the 36' second opener power cable through the PVC conduit and secure in
the driveway slot/trench (see pages 6 and 14).
Step 3
Insert the SECOND power cable into a strain relief slot. Bring power cable into
the control box through a strain relief slot, leaving enough wire to reach the
SECOND OPR. terminal block.
Insert the individual power cable wires into appropriate terminals on the
SECOND OPR. terminal block (white to WHT; green to GRN; red to RED;
black to BLK). Tighten the set screws. A dab of petroleum jelly on each terminal
will help prevent corrosion.
Connect the Transformer
(*Solar Instructions on
IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE:
• The only wire acceptable for use with NSC products is 16 gauge multi-stranded, low voltage, direct burial wire. This
particular gauge enables the transformer to provide an adequate charge through the control board to the battery at
distances up to 1000'.
• DO NOT use telephone wire or solid core wire. Unlike multi-stranded wire, these types of wire are inadequate for use
with your gate opener system.
• NEVER splice wires together. Splicing permits corrosion and seriously degrades the wire's ability to carry an adequate
current.
Step 1
Make sure the power switch is OFF.
Step 2
Select the electrical outlet where you will plug the transformer. Measure the
distance from this outlet to the control box following the path where the wire
will be laid. After you have measured how much wire is needed, cut the wire to
the appropriate length (up to 1000').
VAR5
VAR6
K1
PF1
K2
BATT +
BATT –
K3
K4
VAR4
VAR3
VAR2
VAR1
MIN
MAX OFF
≤JP1
REMOVE JUMPER FOR
PUSH TO OPEN OPTION
120
SEC.
G
TO Inc.
Tallahassee, FL
R4722
STALL FORCE
OPEN < JOG > CLOSE
PWR.
SET
LIMIT
1st OPR.
2nd OPR.
STATUS
AUTO CLOSE
SFTY.
EXIT
CYCLE
EDGE
SENSOR
COMMON
LOCK+
LOCK–
WHT
GRN
RED
BLK
WHT
GRN
SECOND OPR
.
FIRST OPR
.
RED
BLK
CHARGE
ON OFF
Low Voltage Wire from
Transformer or Solar
OR
SOLA
Correct
Wrong
Wrong
Wire
Terminal
Block
Terminal
Block
Terminal
Block
Wire
Wire
NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME!
ON/OFF
Switch
ON/OFF