background image

19

  

MM272 Installation Instructions

PUSH-TO-OPEN

 gates open out from the property (opener arms 

extend

 to open). Push-To-Open Brackets are required for this type 

of installation, one for each gate [FM148] 

page 27

).). In a Push-To-Open installation, the opener is installed while the gate is

 

in 

the closed position and the opener fully retracted. Swinging gates MUST NEVER open into public access areas!

Step 1: Read "Installation of the First Opener" on 

page 7

.

Step 2: Determining The Mounting Position of The Post Bracket Assembly
 

A.  Insert the 

3

/

8

" x 1

1

/

4

" bolt through the center hole of the post brackets and post pivot bracket.  Secure with a 

3

/

8

" washer, 

lock washer and 

3

/

8

" nut. DO NOT

 overtighten 

the nut (the post pivot bracket will have to be adjusted later).Attach post 

bracket assembly to the rear mount of the opener with a clevis pin. Secure the clevis pin with a hairpin clip. Attach gate 

bracket to the front mount of the opener with a clevis pin. Secure 

the clevis pin with a hairpin clip. For pictorial reference see Steps 

1, 2 and 3 on 

page 8

.

 

B.  With the gate in the closed position (up to 110º from its open 

position), and the opener fully retracted, adjust the post bracket 

assembly and gate bracket until the opener is level. While holding 

the opener level, use C-clamps to temporarily keep the post bracket 

assembly and gate bracket in their respective positions on the fence 

post and gate. For pictorial reference see Steps 3 on 

page 8

.

  

IMPORTANT:

 Be sure the position of the gate opener and brackets 

allows for 1" of clearance between the gate and the opener in both 

the open and closed position, while at the same time maintaining 

a stroke distance of 7" to 13" from center of hole in the end of the 

retracted opener arm to the center of the hole in the gate bracket 

with the gate in the open position. This mounting position will 

give the opener the most efficient leverage point for operation and 

provides the least possible pinch area.

 

C.  After verifying that you have the best position for the post pivot 

bracket in the closed position, insert the 

5

/

16

" x 1

1

/

4

" bolt through 

the aligned holes of the post bracket and post pivot bracket to hold 

it in place. Remove the clevis pin from the front mount and 

while 

supporting the gate opener

, swing the gate and gate opener to the 

open

 position. Again, check the clearance and be sure that the gate 

opener is not binding.

  

IMPORTANT:

  If you don't have the required clearance, or if the 

gate opener is binding, remove the 

5

/

16

" x 1

1

/

4

" bolt and readjust 

the post pivot bracket. TIP: Turn the post pivot bracket over for 

more hole alignment options. 

 

D.  When the post pivot bracket assembly is in the optimum position, 

reattach the opener to the gate bracket (gate in the closed position); 

recheck the gate opener level; make sure the brackets are clamped 

securely. Mark reference points for bolt holes on the post through 

middle of post bracket slots. Mark reference points for bolt holes 

on the gate cross member through middle of gate bracket slots. 

After marking your reference points, remove the opener and 

brackets from the post and gate.

  E. Drill 

3

/

8

" holes through post as marked. Fasten post bracket assembly to the post using two 

3

/

8

" x 8" bolts, washers, 

lock washers and nuts

You must use bolts that completely penetrate the post.

 

Drill 

3

/

8

" holes through the gate cross 

member as marked. Mount gate bracket using two 

3

/

8

" x 2 

3/4

" bolts, washers, lock washers and nuts

.  

NOTE: For mounting examples, see 

page 10

.

Push-To-Open Installation Instructions

3/8

" x 1 

1/4

" Bolt

3/8

" Nut

Push-To-Open Bracket

(optional accessory FM148)

Post Bracket

Push-To-Open Bracket Assembly

3/8

" Washer

Lock Washer

Gate in the Closed Position

Pinch Area (gray)

Gate in the Open Position

1" minimum

Pinch Area (gray) 

1" minimum

7" to 13” stroke

Содержание MIGHTY MULE MM272

Страница 1: ...o control box from transformer wire not included Power Cable Gate Bracket Warning Sign First Gate Opener Post Bracket Second Gate Opener Gate Bracket Horizontal Support PVC conduit not included to run...

Страница 2: ...operly following all installation and safety instructions you may return this product for full replacement value READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to install and use thi...

Страница 3: ...tallation of the FIRST Gate Opener 7 Install Post Bracket Assembly and Gate Bracket 8 Attach Opener Arm 10 Install the Closed Position Stop Plates 11 Mount the Control Box 12 Connect Opener Power Cabl...

Страница 4: ...n vinyl aluminum chain link farm tube and wrought iron gates Use on solid surface gates is not recommended Solid surface gates have a high resistance to the wind If the wind is strong enough the opera...

Страница 5: ...s of the gate operator the safety precautions and warnings contained in Disconnecting the Operator 1 Turn control box power switch OFF 2 Remove hairpin clip clevis pin and bushing from either the fron...

Страница 6: ...tomatic gate system where a person or object could be caught that increase the risk of injury Entrapment zones must be eliminated guarded or protected 8 When designing a system that will be entered fr...

Страница 7: ...located at least 10 feet from any moving part of the gate see diagram below Never install any control device where a user will be tempted to reach through the gate to activate the gate operator 5 Do...

Страница 8: ...before performing any maintenance See page 26 for maintenance procedures 7 To operate this equipment safely YOU must know how to disconnect the operator for manual gate operation see page iii If you...

Страница 9: ...locked or impeded by building structures natural landscaping or similar objects Entrapment Alarm The Mighty Mule Automatic Gate Operator is designed to stop and reverse the gate when the gate comes in...

Страница 10: ...n gates used for vehicles Pedestrians must be supplied with a separate access opening The pedestrian access opening shall be designed to promote pedestrian usage Locate the gate such that persons will...

Страница 11: ...ate is for vehicles only Pedestrians must use separate entrance Moving gate can cause injury or death 1 TENEZ VOUS LOIN La barri re peut se d placer tout moment 2 Lisez toutes les instructions de s cu...

Страница 12: ...y connected to any battery Do not replace fuses with higher ampere rated fuses doing so will void your warranty and may damage your control board _____________________________________ CONTROL ________...

Страница 13: ...of cover or housing must be used If your gate is more than 1000 from an AC power source you will need to use a solar panel charging kit minimum 10 watts Refer to the Solar Panels and Gate Activity Cha...

Страница 14: ...ting the gate bracket is also important Trench the driveway in order to lay PVC conduit for the second opener power cable see illustration on page 6 Your Property Your Property Pull To Open arm retrac...

Страница 15: ...e Opener 2 Gate Bracket 2 Post Pivot Bracket 2 3 8 Lock Washer 10 Literature Kit Post Bracket 2 Closed Position Stop Plate 2 2 Mounting Screw 3 E Z GATE OPENER Transformer 1 RB503 Battery Wire Harness...

Страница 16: ...upply and the control box page 13 20 If your gate is more than 1000 away from an AC power source you will need to use at least one 10 watt Solar Panel FM123 to charge the 12 Volt battery page 2 26 PVC...

Страница 17: ...open and closed position at the same time maintaining a stroke distance of 7 to 13 from center of hole in the end of the retracted opener arm to the center of the hole in the gate bracket with the gat...

Страница 18: ...post On wood posts place a metal plate or washer not supplied between the nuts and the post to prevent the thrust of the opener from pulling the bolts and washers out of the wood The post pivot bracke...

Страница 19: ...with a clevis pin Secure the clevis pin with a hairpin clip Step 4 With the gate in the fully open position and the opener arm fully retracted adjust the post bracket assembly and gate bracket until t...

Страница 20: ...bracket assembly to different positions on the post If you are mounting to a post or column larger than 8 or you can not achieve the mentioned clearances you can 1 eliminate the post pivot to try and...

Страница 21: ...Remove excess bolt length with hacksaw or bolt cutters SIDE VIEW TOP VIEW EXAMPLES Post Bracket Mounting Examples Attach Opener Arm Step 1 Attach the opener to the securely bolted post bracket assembl...

Страница 22: ...ove the gates to the closed position Step 2 Using appropriate hardware for your type of gate U bolts for tube or chain link screw or bolts for wood or metal attach the closed position stop plate horiz...

Страница 23: ...VIEW SIDE VIEW Closed Position Stop Plate Low Profile Ground Stop Closed Position Stop Plate Step 4 Using appropriate hardware for your type of gate attach the vertical closed position stop plate to t...

Страница 24: ...C products is 16 gauge multi stranded low voltage direct burial wire This particular gauge enables the transformer to provide an adequate charge through the control board to the battery at distances u...

Страница 25: ...the 16VDC OR SOLAR terminals regardless of color polarity Tighten set screws against exposed end of wires A dab of household petroleum jelly on each terminal will help prevent corrosion First Gate Op...

Страница 26: ...ds to the transformer terminals A dab of household petroleum jelly on each terminal will help prevent corrosion We suggest adding crimp on fork lugs to the end of each wire before attaching it to the...

Страница 27: ...et and transformer should be protected by a weatherproof cover Set the CLOSED Position Limit for PULL TO OPEN Installation Your transmitter must be able to operate the gate If not see Personalize Your...

Страница 28: ...l on a radio It controls the amount of force the opener will apply to an obstruction before it automatically reverses direction The Stall Force adjustment is located on the control board Turn the STAL...

Страница 29: ...radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference...

Страница 30: ...the gate in the open position This mounting position will give the opener the most efficient leverage point for operation and provides the least possible pinch area C After verifying that you have th...

Страница 31: ...se the JOG OPEN and CLOSE buttons to fine tune the gate position if necessary C Press and HOLD the SECOND Opener OPEN button on the control board and be prepared to RELEASE the button when the gates r...

Страница 32: ...he wires can be connected to the 16VDC OR SOLAR terminals regardless of color polarity Step 3 Tighten set screws against exposed end of wires A dab of household petroleum jelly on each terminal will h...

Страница 33: ...RST OPR RED 7 8 6 5 4 3 2 AUTOMATIC GATE LOCK ELECTRON IC SECU RITY LOCK 7 8 3 6 Red Blue Black Shield Yellow VAR5 VAR6 K1 PF1 K2 BATT BATT K3 K4 VAR4 VAR3 VAR2 VAR1 MIN MAX OFF JP1 REMOVE JUMPER FOR...

Страница 34: ...t this input will cycle the operation as follows OPEN STOP CLOSE STOP OPEN 4 EDGE Typically for use with contact edge sensor Activation of this input while gate is moving will cause it to reverse dire...

Страница 35: ...ally shut off after 5 minutes gate will remain disabled until control box is restarted d 1 beep every 20 seconds Low battery is detected e 1 beep every 2 seconds Position sensor on first opener is ope...

Страница 36: ...1 First use the procedures found in the Visual and Audible Diagnostic Indicators section page 24 2 Use the 24 7 Troubleshooting Wizard located at www mightymule com 3 If you are unable to solve the pr...

Страница 37: ...eypad The Mighty Mule Wireless Keypad is designed to control access to all Mighty Mule Garage Door Openers This keypad features a LED back light that allows you to see numeric keys throughout dark or...

Страница 38: ...devices This specially designed wire is UV treated PVC coated and ready for direct burial Push to Open Bracket FM148 Required when Mighty Mule gate opener must push the gate open such as on a sloping...

Страница 39: ...side of the gate in highly visible locations These signs must remain at all times 6 There are no controls installed on the gate operator or within 10 feet of the gate 7 The Dual Sense Technology featu...

Страница 40: ...ty Control LLC America s DIY Automatic Gate Openers is a trademark of Nortek Security Control LLC and are the exclusive property of Nortek Security Control LLC NSC All rights are reserved by NSC and t...

Отзывы: