Position the Robot and Install and Connect Components
Refer to the Quick Start Guide and to this section as needed to install the system components and make
connections.
NOTES:
• The components of an automated dispensing system vary. Steps for a complete system with all available
components are provided in this manual and in the Quick Start Guide. Perform only the steps that apply to your
system.
• If the system is being used in the European Community, the robot is shipped with an enclosure or light curtain
that (1) prevents an operator from entering the robot’s work area and (2) generates an emergency stop signal if the
enclosure door switch is opened while the robot is running.
Applicability
Item
Components to Install
or Connect
Installation Tasks
All models
Input/output
safety plug
(SHORTED)
Connect the input/output safety plug to the
Ext. Control port to bypass the door switch.
CAUTION
Install this plug only if you want to bypass the
door switch. When this plug is installed, the
customer assumes all safety liability.
All models
DispenseMotion
controller
Mount the DispenseMotion controller on
the shelf.
Install the shelf-and-controller assembly on
the left upright bracket.
Make the connections shown on the Quick
Start Guide.
All models
CCD camera
Fixed-
mount
R-mount
(Optional for the fixed-mount camera only)
Install the provided optional lenses.
Install the camera and bracket assembly.
Connect the camera cable to the camera.
Route the camera cable through the dragon
chain on the Z axis.
Connect the cable to USB-CCD on the
DispenseMotion controller.
All models
Tip detector or tip
aligner (optional)
Install the tip detector or tip aligner.
Connect the cable to the Tactile port on the
back of the robot.
Continued on next page