RV Series Automated Dispensing Systems
51
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Setting Up the System Using the Robot Initial Setup Wizard (continued)
Robot Initial Setup (Step 1 Tab): Setting Up Tip Detection and Tool Centering Calibration
(continued)
Function of the Test-Move Buttons in the Robot Initial Setup Wizard
Use the buttons at the bottom of the Robot Initial Setup window to verify settings at any time during the setup
process.
Button
Function
Reference Image
Needle
to C
Moves the tip to the calibration point that was
2 mm above the tip detection device.
Needle to
B-5 mm
Moves the tip to 5 mm above the point used for
the tool centering calibration.
Needle
to B
Moves the tip to the point used for the tool
centering calibration.
Needle
to A
Moves the tip to the test deposit location.
CCD to A
Centers the camera over the test deposit location.
Reset the
4 Axis
Resets the tool centering calibration calculation.
#
Click
Step
Reference Image
7
• Click CALCULATE.
The system performs the tool centering
calibration. This calibration ensures that the
tip stays centered over the same point while
rotation occurs, even as the X and Y axes
adjust the location of the workpiece.
NOTE:
To test the setup, use the buttons at
the bottom of the wizard. Refer to “Function
of the Test-Move Buttons in the Robot
Initial Setup Wizard” below for detailed
information.
8
>
• Click SAVE.
• Click NEXT.
9
• Continue to “Robot Initial Setup (Step 2