Item
Screen Capture
Description
Auto Purge
Run Limit
Fluid Working
Life
To set up automatic purge settings, run limits, or fluid working life limits
for a program, refer to “How to Set Up Auto Purge, Program Cycle
Limits, or Fluid Working Life Limits” on page 84.
Other
•
Pre-cycle Initialize:
If checked, the robot always moves to the home
position (0, 0, 0) before the start of a dispense cycle.
•
Needle XY Adjust:
Enables or disables the Needle XY Adjust
capability. When Needle XY Adjust is checked, the Needle XY Adjust
button appears on the Program screen.
•
Tip Detect Device:
Indicates that the system includes the optional tip
detector or tip aligner. When Tip Detect Device is checked, the Needle
Z Detect button appears on the Program screen and the capability is
enabled in the Robot Initial Setup wizard. If unchecked, the capability
is disabled in the Robot Initial Setup wizard.
•
2D Code:
Check this box to enable or disable QR code scanning
capability. Refer to “Appendix D, QR Code Scanning Setup” on
page 134 to set up QR code scanning.
•
Multi Needles:
To dispense using more than one dispenser (up to four
•
Height Sensor:
Not currently available.
•
Set Z to Focus:
Sets whether the system captures the current
Z height value in command windows. For RV systems, uncheck this
box.
•
Save Image (OptiSure AOI only):
When checked, the system
automatically saves image files for applicable OptiSure AOI functions.
•
Comment XYZ:
When checked, any changes made to the tip height
(either the Tip Detect Device or Z Clearance settings on the System
Setup screen) will affect commands, even if a command is disabled.
•
Image Stretch/Shrink:
This system setting is useful if a workpiece
stretches or shrinks in size after extended use or after a process step
(such as baking). When this setting is checked, the system allows any
fiducial mark to adjust accordingly if a workpiece stretches or shrinks.
NOTE:
The fiducial mark must still fit within the camera’s field of view,
which means there is a limit to how much stretching or shrinking the
system can accommodate.
Continued on next page
Setting System Parameters (continued)
System Setup Screen Fields (continued)