Fleck 5600 SXT 
MeTered WaTer SoFTener

I n s ta l l at I o n   G u I d e

 v1.0

Содержание 5600SXT

Страница 1: ...Fleck 5600 SXT Metered Water Softener Install ation Guide v1 0...

Страница 2: ...values of H hARDNESS C UNIT cAPACITY and Bf bRINE FILL The remaining values that are already filled in are general standards for all softener sizes and hardness levels MASTER PROGRAMMING MODE To enter...

Страница 3: ...e of a new water softener with Fleck 5600 SXT Meter Control Valve from QualityWaterForLess com We have put together these instructions as reference and to be used as general installation guidelines It...

Страница 4: ...L are the same measure and both figures can be used interchangeably If you get a hardness level in PPM or mg L please divide this number by 17 1 to get Grains gpg Ex If your hardness is measured at 3...

Страница 5: ...K 12 Min 18 lbs TOO SMALL Grid 3 Legs Grid 3 Legs Grid 3 Legs Grid 6 Legs Grid 6 Legs 12 25 gpg 81K 20 Min 30 lbs TOO SMALL TOO SMALL Grid 6 Legs Grid 6 Legs 25 gpg 96K 30 Min 45 lbs TOO SMALL TOO SMA...

Страница 6: ...ig u r e 6 a Fig u r e 6 B pre install ation Before assembly of your new system be sure that the following conditions have been met for the place ment of your system Level firm surface such as concret...

Страница 7: ...stalling the fleck 5600 sx t Valve 1 Using caution not to lift the riser tube remove the filling funnel and tape While using the included silicone lubricant packet lu bricate the inner and outer o rin...

Страница 8: ...lines and use a wet rag on the lines being soldered to prevent heat damage during soldering 6 Once all connections have been made place the system into bypass by either using your existing 3 valve byp...

Страница 9: ...lso take this moment to prepare and insert the brine support grid determined from pages 4 and 5 Then pull the 474 Brine Float Assembly out of the brine well as shown in Figure 9 C 4 Next fix the 474 B...

Страница 10: ...be evenly press on both sides of the grey ring surrounding the tube and pull out as shown in Figure 10 A i Be sure to recut the end of the tube each time you remove it to ensure a proper seal when the...

Страница 11: ...ime to scroll faster Once the time display is set to 12 01 PM press the REGEN button once as shown in Figure 11 B 3 To enter MASTER PROGRAMMING MODE press the UP and DOWN buttons TOGETHER and HOLD bot...

Страница 12: ...your water listed on page 2 calculated on page 4 and press the REGEN button as shown in Figure 12 C 10 The display should now show RS SF as shown in Figure 12 D This indicates that the Reserve Selecti...

Страница 13: ...Figure 13 A This indicates the system will regenerate at 2 00 AM following the day the water consumption has passed the calculated capacity If you prefer an alternate regeneration time please enter i...

Страница 14: ...reen stops flashing BW let BW Backwash run for about 1 minute to observe the water leave out the drain line and check for leaks If you notice any leaks return to page 10 to review preparing the drain...