![Nordson Encore LT Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/nordson/encore-lt/encore-lt_product-manual_1704414067.webp)
Repair
6-11
Part 1604857-04
E
2014 Nordson Corporation
Vibrator Motor Replacement
When replacing the motor, make sure you order the correct motor for your
voltage. Vibrator motors include the power cable.
1. Remove the front panel from the dolly tower, then dismount the
controller.
2. Remove the screws securing the rear panel to the controller enclosure,
then carefully slide the rear panel out of the enclosure.
3. Disconnect the vibrator motor cable from the relay board, then loosen
the cord grip and pull the cable out of the panel.
4. Route the new motor cable through the cord grip, then connect the cable
leads to the relay board as shown below. Make sure the relay board
jumper is set for the correct voltage.
ENCORE LT
RELAY PCA
J1
C2
C1
RL1
F1
F2
M1 M2 M3
JP1
1
2
L2 F
L2
L1 F
L1
Jumper JP1 for 115V Motor
Remove Jumper for 230V Motor
M1 M2 M3
(GREEN)
(BLACK)
(RED)
(WHITE)
115V MOTOR
230V MOTOR
M1 M2 M3
(YEL/GRN)
(BLACK)
(BLUE)
(BROWN)
VBF POWER CORD WIRING
Figure 6-14 Vibrator Motor Connections
Содержание Encore LT
Страница 4: ...Change Record ii Part 1604857 04 E 2014 Nordson Corporation ...
Страница 12: ...Safety 1 4 Part 1604857 04 E 2014 Nordson Corporation ...
Страница 34: ...System Setup 3 18 Part 1604857 04 E 2014 Nordson Corporation ...
Страница 56: ...Troubleshooting 5 8 Part 1604857 04 E 2014 Nordson Corporation ...
Страница 68: ...Repair 6 12 Part 1604857 04 E 2014 Nordson Corporation ...
Страница 86: ...Parts 7 18 Part 1604857 04 E 2014 Nordson Corporation ...
Страница 87: ...Wiring Diagram 8 1 Part 1604857 04 E 2014 Nordson Corporation Section 8 Wiring Diagram ...
Страница 88: ...Wiring Diagram 8 2 Part 1604857 04 E 2014 Nordson Corporation ...
Страница 92: ...ZONE REV DESCRIPTION BY CHK RELEASE NO DATE SEE SHEET 1 FOR REVISION HISTORY ...