4 Technical Specifications
BLUE CURE FL-8.0W-125X20-WC-
Outer dimensions L x W x H
(including the tube for
the cooling connection)
135 x 49 x 76 mm
Dimensions of the
light-emitting window
125 mm x 20 mm
Maximum intensity of radiation
8.0 W/cm
2
Fastening thread - broad sides
2x M3 x 0.5 each; maximum 6 mm deep;
Tightening torque: maximum 0.36 Nm
Axial force: maximum 85 kN
Fastening thread - long sides
4x M2.5 x 0.45 each; maximum 5 mm deep;
Tightening torque: maximum 0.9 Nm
Axial force: maximum 85 kN
Weight
0.48 kg
Operational voltage
+48 V DC
Power consumption
25 A
Power supply
BLUE CURE POWER AC-48V-32.0A
http://www.meanwell.com/search/rsp-1500/rsp-1500-spec.pdf
(RSP-1500-48)
Operational temperature
+10°C to +40°C
Humidity
maximum of 80 % rel. humidity, non-condensing at +30°C
Area of use
Below 2000 meters of elevation
Storage temperature
-20 to +85°C
Cooling
Liquid cooled
Connection for the coolant intake
and outlet
1x brass tube each; Ø 9.5 mm
Coolant
softened water with anti-algae additive
Cooling output
minimum of 1000 W
Through-flow rate
minimum of 4 to 6 liters/min.
Coolant temperature at the intake
maximum of +20°C
Coolant pressure
maximum of 8.3 bar
Loss of pressure in the light source 0.14 bar at 4 liters/min.
0.27 bar at 6 liters/min.
with a coolant temperature of +20°C respectively
Gauge of the coolant lines
10/8 hose line
Material of the coolant lines
PE, PU, nylon