13
CAUTION!
Note:
All input and output signals of the lamp must have the same ground as the
+48 V DC power supply.
Temperature fault and SLM error diagram ‘Open commutator TTL output’
If desired, pins 5 and 11 can be joined together for a single error as an output signal.
CAUTION!
Attention:
Both outputs ‘Pin 5 and 11’ are not short-circuit-proof and may carry a
maximum of 5 mA.
If multiple light sources are used together simultaneously, the following pins can be
looped through:
- Pin 2
Input – amp output
- Pin 3 or 4
Input – turn on lamp with a high or low signal
- Pin 5
Output temperature fault
- Pins 8, 9, 10, 14
References masses
- Pin 11
Output SLM error
- Pin 7
Emergency shut-off functionality
Do not connect the following pins for any reason:
- Pin 6
5 V DC
- Pin 15
Output temperature monitor
Содержание BlueCure FL
Страница 2: ...2...
Страница 20: ...20 A Appendix A 1 Drawing of the BLUE CURE FL 8 0W 125X20 WC 395...