quality | efficacy | design
L I G H T I N G
quality | efficacy | design
PHOS 75, PHOS 50, PHOS 32 LED FLOOD LIGHTS
INSTALLATION MANUAL
1
of
2
GENERAL INFORMATION
A qualified electrician should carry out wiring connection to the mains supply in accordance with local IEE wiring regulations.
Isolate the mains supply before commencing installation.
Do not connect to a circuit which also has inductive loads connected as spikes generated switching inductive loads may damage electronic components within your luminaire
Do not carry out high voltage insulation testing as this may damage internal components.
The chosen location of your new fitting should allow for the product to be securely mounted and safely connected to the mains supply (Lighting circuit).
Ensure that the fitting will be accessible after installation for maintenance.
Ensure the product is free from damage. Do not attempt to install damaged products please contact manufacturer.
The product should not be disassembled or modified in any way. Doing so will invalidate all warranties.
Do not install the fitting with the glass facing vertically upwards.
To clean the exterior of your LED floodlight use a clean dry cloth. Avoid chemicals and abrasive cleaners.
INSTALLATION
Isolate the mains supply before commencing installation.
The flood light is supplied with a 3 core flex:
Live: Brown
Neutral: Blue
Earth: Green and Yellow
1. Determine the location of your luminaire. If any access equipment is required ensure the operator adheres to all health & safety regulations and has the appropriate licence/
qualifications.
2. Make a mark against the wall where the drill holes need to be placed by aligning the light’s bracket against the wall.
Warning! Before drilling hole(s) into a wall, check that there are no hidden obstructions like pipes, cables and wires, within its surface.
3. Drill into the mounting surface where the marks have been made with a suitable size drill bit. The mounting bracket will take a maximum of 10mm bolts
4. Secure the fitting in place and ensure the fixing bolts are securely tightened and the fitting is safe and free from any vibration.
5. Connect the 3 core flex supplied with the luminaire to your mains supply using the appropriate junction/connector box. We recommend as a minimum an IP65 rated junction box.