background image

12

Pin Function

Signal Level

Remark

1

---

---

Do not connect

2

Input
Lamp output

0 to +5 V DC

The desired lamp output is achieved depending on the input voltage (+5 V
= 100 %, +1 V = 20 %).  The smallest input voltage for the proper
function of the lamp is +1 V.  
Note: A connection with pin 6 results in 100% output in the case of Rin 10 k

3

Input 
Turn on lamp 
with high signal

0 or +5 V DC

TTL (Transistor-Transistor-Logic):
0 to +0.4 V DC = Lamp off (open input = off)
+3.5 to +5 V DC = Lamp on
Note:  Beyond the listed values, the lamp operates in an undefined
condition.

4

Input
Turn on lamp 
with low signal

0 or +5 V DC

TTL (Transistor-Transistor-Logic): 
0 to +0.4 V DC = Lamp on 
+3.5 to +5 V DC = Lamp off (open input = off)
Note:  Beyond the listed values, the lamp operates in an undefined
condition.

5

Output 
Temperature fault

0 or +5 V DC

Open commutator TTL output:
0 to +0.4 V DC = temperature fault 
+3.5 to +5 V DC = no temperature fault
Leakage current:  maximum 5 mA (see diagram following this table) 
Note:  Beyond the listed values, the lamp operates in an undefined
condition.  The pins 5 and 11 can be connected with each other for a
common error output (see explanation and diagram following this table).
The remarks regarding the use of the output under 7 Intensity of the
Radiation must also be complied with.

6

Output
+5 V DC

+5 V DC

The reference voltage is only intended for the operation of the lamp.  
Improper use of this voltage for other purposes can cause damage to the
lamp. 
Connect pin 6 with pin 2 for a constant 100% lamp output.

7

Emergency 
shut-off
functionality

0 or +5 V DC

For the connection to a latch circuit at the facility.
0 to +0.4 V DC = release
+3.5 to +5 V DC = no release
Note:  Beyond the listed values, the lamp operates in an undefined
condition.  If a latch circuit is not present at the facility, pin 7 must be
connected with a ground pin (pin 14).

8

Reference mass 0 V DC

---

9

Reference mass 0 V DC

---

10 Reference mass 0 V DC

---

11 Output 

SLM error

0 or +5 V DC

Open commutator TTL output: 
0 to +0.4 V DC = error 
+3.5 to +5 V DC = no error
Leakage current:  maximum 5 mA (see diagram following this table) Note:
Beyond the listed values, the lamp operates in an undefined condition.  The
pins 5 and 11 can be connected with each other for a common error
output (see explanation and diagram following this table).

12 ---

---

Do not connect

13 ---

---

Do not connect

14 Reference mass 0 V DC

---

15 Output 

Temperature
monitor

0 to +7,5 V DC The output voltage is proportional to the SLM of the cooling element.

The value should not 5 V DC.
Conversion factor:  0.1 V/°C (e.g. +30 °C = 3.0 V DC) 

5.1 SPS Connection

Содержание BlueCure FL

Страница 1: ...ure FL Please read this user manual carefully before initial operation Electronic pdf files of EFD manuals are also available at www nordsonefd com IMPORTANT Save this Sheet Forward to Maintenance or...

Страница 2: ...2...

Страница 3: ...nd Inspection 9 3 Functionality 9 4 Technical Specifications 10 5 Installation 11 16 5 1 SPS Connection 12 13 5 2 Power Supply Connection 14 5 3 Possible Connection Scenarios 15 16 6 On Off Control 16...

Страница 4: ...azards DANGER This symbol indicates a direct hazard to the life and health of persons WARNING This symbol indicates a potential hazard to the life and health of persons CAUTION This symbol indicates a...

Страница 5: ...gh intensity UV LED emitting devices for industrial applications To achieve short hardening times of the UV hardened materials intense UV radiation is necessary The standard CEI IEC 62471 describes th...

Страница 6: ...d in IEC 62471 Risk free means that based on this standard there is no health hazard through irradiation Risk Group 1 Low risk Does not pose an irradiation hazard under normal performance and use Risk...

Страница 7: ...in a distance 1 5 meters from the light source in order to protect eyes and skin Eye protection must be provided for work in the area within a distance of 1 5 to 3 meters from the point of the LED whe...

Страница 8: ...subject to the EU Guidelines of the Chemicals Directive REACH Furthermore with regard to the planned candidate list of substances of very high concern SVHC issued on October 10 2008 Nordson EFD decla...

Страница 9: ...e UV intensity correlates to that of a mercury vapor lamp with frequent electrical power consumption The BlueCure lamps are comprised of closely arranged semi conductor light emitting diodes that are...

Страница 10: ...POWER AC 48V 32 0A http www meanwell com search rsp 1500 rsp 1500 spec pdf RSP 1500 48 Operational temperature 10 C to 40 C Humidity maximum of 80 rel humidity non condensing at 30 C Area of use Below...

Страница 11: ...if it is mounted or integrated in a system using the fastening threads The lamp is connected to the liquid cooling system using the appropriate connections and its functionality and seals are checked...

Страница 12: ...regarding the use of the output under 7 Intensity of the Radiation must also be complied with 6 Output 5 V DC 5 V DC The reference voltage is only intended for the operation of the lamp Improper use...

Страница 13: ...utputs Pin 5 and 11 are not short circuit proof and may carry a maximum of 5 mA If multiple light sources are used together simultaneously the following pins can be looped through Pin 2 Input amp outp...

Страница 14: ...in or disconnect the plug while under voltage For this purpose turn the power supply off first V V PE V V Pin Function Signal Level Remark V Input voltage 47 to 49 V DC 48 V DC input to the power sup...

Страница 15: ...ensity from 20 to 100 No monitoring of errors and temperature Temperature monitoring via an external voltmeter No emergency shut off functionality S1 On off lamp T1 Power supply S1 On off lamp V1 exte...

Страница 16: ...prevent heat from building Even if the surface of the lamp does not heat up high temperatures may develop in the area surrounding the lamp e g every material in the direct proximity for which there is...

Страница 17: ...on Because the coolant extensively cools the cooling element of the lamp in certain operating conditions for expelling heat condensation may form in the lamp behind the glass of the light emitting wi...

Страница 18: ...r cleaning the lamps 1 Run a solution consisting of vinegar and decalcified water Mixing ratio 1 1 n weight through the lamp for 15 minutes 2 In the next step run a pure vinegar solution through in th...

Страница 19: ...ergency shut off functionality Bridge between pin 7 and grounding pin 14 Lamp output Bridge between pin 2 and pin 6 SLM error Check the wiring of the DB15 connection see 5 1 SPS Connection for this If...