BlueCure lamps are classified as a risk group 3 in accordance with IEC 62471 when
in the vicinity and when looking directly at the source of the radiation.  When
integrating the source of radiation into a production system, the risk must generally
be ranked as low to medium if the appropriate distances from the user are ensured
or risk-free in the case of appropriately specified integration schemes.

Looking directly at the light source is dangerous, therefore, it is imperative to wear
safety glasses, e.g. UVEX SCT orange lenses.

The BlueCure lamps are classified as class 3B LEDs in accordance with the
international standard IEC 60825-1:2001.  Contrary to laser devices, there is NO
requirement to register devices of this type with a professional association or trade
control.  Hiring a laser protection commissioner in the company is NOT necessary.

Primarily organizational and technical protective measures have to be met in areas
in which class 3B LED devices are operated.  If this is not possible, appropriate eye
protection devices, protective clothing or protective gloves must be provided for
work in this area within a distance <1.5 meters from the light source in order to
protect eyes and skin.  Eye protection must be provided for work in the area within
a distance of 1.5 to 3 meters from the point of the LED where light is emitted.  Skin
protection measures are no longer necessary in this case due to the extremely low
intensity of the radiation.

The maximum permissible value for the UV exposition is 83 J/cm2 for a wavelength
of 395 nm.

The described lamps are operational resources for use in industrial facilities.  Those
responsible for the safety of the systems must therefore ensure that

• Work on or in the proximity of the BlueCure lamps is conducted only by

sufficiently qualified personnel.

• These persons already have access to the user manual and other product

documentation, etc. and are required to comply with these documents
consistently when executing the respective operations.

CAUTION! 

Note:

Qualified personnel are persons who, due to their training, experience and
instruction, as well as their knowledge of relevant standards, provisions,
accident prevention regulations and operating conditions, have been
authorized by the person responsible for the safety of the system to perform
the required tasks and, in the process, can identify and prevent potential
risks (definitions for specialists according to VDE 105 or ICE 364). 

Содержание BlueCure FL

Страница 1: ...ure FL Please read this user manual carefully before initial operation Electronic pdf files of EFD manuals are also available at www nordsonefd com IMPORTANT Save this Sheet Forward to Maintenance or...

Страница 2: ...2...

Страница 3: ...nd Inspection 9 3 Functionality 9 4 Technical Specifications 10 5 Installation 11 16 5 1 SPS Connection 12 13 5 2 Power Supply Connection 14 5 3 Possible Connection Scenarios 15 16 6 On Off Control 16...

Страница 4: ...azards DANGER This symbol indicates a direct hazard to the life and health of persons WARNING This symbol indicates a potential hazard to the life and health of persons CAUTION This symbol indicates a...

Страница 5: ...gh intensity UV LED emitting devices for industrial applications To achieve short hardening times of the UV hardened materials intense UV radiation is necessary The standard CEI IEC 62471 describes th...

Страница 6: ...d in IEC 62471 Risk free means that based on this standard there is no health hazard through irradiation Risk Group 1 Low risk Does not pose an irradiation hazard under normal performance and use Risk...

Страница 7: ...in a distance 1 5 meters from the light source in order to protect eyes and skin Eye protection must be provided for work in the area within a distance of 1 5 to 3 meters from the point of the LED whe...

Страница 8: ...subject to the EU Guidelines of the Chemicals Directive REACH Furthermore with regard to the planned candidate list of substances of very high concern SVHC issued on October 10 2008 Nordson EFD decla...

Страница 9: ...e UV intensity correlates to that of a mercury vapor lamp with frequent electrical power consumption The BlueCure lamps are comprised of closely arranged semi conductor light emitting diodes that are...

Страница 10: ...POWER AC 48V 32 0A http www meanwell com search rsp 1500 rsp 1500 spec pdf RSP 1500 48 Operational temperature 10 C to 40 C Humidity maximum of 80 rel humidity non condensing at 30 C Area of use Below...

Страница 11: ...if it is mounted or integrated in a system using the fastening threads The lamp is connected to the liquid cooling system using the appropriate connections and its functionality and seals are checked...

Страница 12: ...regarding the use of the output under 7 Intensity of the Radiation must also be complied with 6 Output 5 V DC 5 V DC The reference voltage is only intended for the operation of the lamp Improper use...

Страница 13: ...utputs Pin 5 and 11 are not short circuit proof and may carry a maximum of 5 mA If multiple light sources are used together simultaneously the following pins can be looped through Pin 2 Input amp outp...

Страница 14: ...in or disconnect the plug while under voltage For this purpose turn the power supply off first V V PE V V Pin Function Signal Level Remark V Input voltage 47 to 49 V DC 48 V DC input to the power sup...

Страница 15: ...ensity from 20 to 100 No monitoring of errors and temperature Temperature monitoring via an external voltmeter No emergency shut off functionality S1 On off lamp T1 Power supply S1 On off lamp V1 exte...

Страница 16: ...prevent heat from building Even if the surface of the lamp does not heat up high temperatures may develop in the area surrounding the lamp e g every material in the direct proximity for which there is...

Страница 17: ...on Because the coolant extensively cools the cooling element of the lamp in certain operating conditions for expelling heat condensation may form in the lamp behind the glass of the light emitting wi...

Страница 18: ...r cleaning the lamps 1 Run a solution consisting of vinegar and decalcified water Mixing ratio 1 1 n weight through the lamp for 15 minutes 2 In the next step run a pure vinegar solution through in th...

Страница 19: ...ergency shut off functionality Bridge between pin 7 and grounding pin 14 Lamp output Bridge between pin 2 and pin 6 SLM error Check the wiring of the DB15 connection see 5 1 SPS Connection for this If...

Страница 20: ...20 A Appendix A 1 Drawing of the BLUE CURE FL 8 0W 125X20 WC 395...

Страница 21: ...21...

Страница 22: ...Y Nordson EFD products are warranted for one year from date of purchase to be free from defects in material and workmanship but not against damage caused by misuse abrasion corrosion negligence accide...

Отзывы: