![NorAM 65E Turbo Motor Grader Скачать руководство пользователя страница 823](http://html1.mh-extra.com/html/noram/65e-turbo-motor-grader/65e-turbo-motor-grader_service-manual_1700491823.webp)
ZF Friedrichshafen AG
description of fault codes for ERGO-Control
97-09-18
TE-AB
F:\15_Kunden_Informationen\FC_Liste\Fc_37_V920.doc
Seite 53 von 58
Fault
Code
(hex)
SPN FMI Int.
Code
(dec)
MEANING OF THE FAULT CODE
possible reason for fault detection
reaction of the TCU
possible steps to repair
remarks
costu
mer
measured voltage at power supply is lower
than 10 V (12V device)
lower than 18 V (24V device)
OP-Mode: TCU shutdown
•
check cables from batteries to TCU
•
check connectors from batteries to TCU
Sisu
D4
5820
3
52
HIGH VOLTAGE AT BATTERY
measured voltage at power supply is
higher than 18 V (12V device)
higher than 32.5 V (24V device)
shift to neutral
OP-Mode: TCU shutdown
•
check power supply battery
•
check cables from batteries to TCU
•
check connectors from batteries to TCU
all,
Sisu
D5
5830
2
57
ERROR AT VALVE POWER SUPPLY
VPS1
TCU switched on VPS1 and measured
VPS1 is off or TCU switched off VPS1
and measured VPS1 is still on
•
cable or connectors are defect and are
contacted to battery voltage
•
cable or connectors are defect and are
contacted to vehicle ground
•
permanent power supply KL30 missing
•
TCU has an internal defect
shift to neutral
OP-Mode: TCU shutdown
•
check fuse
•
check cables from gearbox to TCU
•
check connectors from gearbox to TCU
•
replace TCU
all,
Sisu
D6
5840
2
58
ERROR VALVE POWER SUPPLY
VPS2
TCU switched on VPS2 and measured
VPS2 is off or TCU switched off VPS2
and measured VPS2 is still on
•
cable or connectors are defect and are
contacted to battery voltage
•
cable or connectors are defect and are
contacted to vehicle ground
•
permanent power supply KL30 missing
•
TCU has an internal defect
shift to neutral
OP-Mode: TCU shutdown
•
check fuse
•
check cables from gearbox to TCU
•
check connectors from gearbox to TCU
•
replace TCU
all,
Sisu
D7
5545
4
S
.
C
.
TO GROUND AT
DLM
L
ONGITUDINAL
OUTPUT
TCU detected a wrong voltage at the
output pin, that looks like a s.c. to vehicle
ground
•
cable is defective and is contacted to
output will be on until TCU
power down even if fault
vanishes (loose connection)
OP-Mode: normal
•
check the cable from TCU to the valve
•
check the connectors
•
check the resistance of valve
1)
see chapter 4
all
Содержание 65E Turbo Motor Grader
Страница 2: ...This page intentionally left blank ...
Страница 7: ...Service Manual Section 1 Electronic Display Service 2 00_2013 03 ...
Страница 33: ...Service Manual Section 2 Engine Service 2 00_2013 03 ...
Страница 34: ......
Страница 70: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 2 26 Section 2 Engine CAT Tier IVi Fuses ...
Страница 75: ...Service Manual Section 3 Operator s Platform and Controls Service 2 00_2013 03 ...
Страница 76: ......
Страница 90: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 3 4 Section 3 Operator s Platform and Controls Cab ...
Страница 92: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 3 6 Section 3 Operator s Platform and Controls ...
Страница 121: ...Service Manual Section 4 Transmission Service 2 00_2013 03 ...
Страница 122: ......
Страница 149: ...ERGOPOWER Geschäftsbereich Arbeitsmaschinen Antriebe und Achssysteme 2 1 Edition ...
Страница 171: ......
Страница 202: ...Order No 5871 146 002 ZF ERGOPOWER 6 WG 115 ZF Passau GmbH Donaustr 25 71 D 94 034 Passau ...
Страница 330: ...Service Manual Section 5 Front Axle Service 2 00_2013 03 ...
Страница 331: ......
Страница 339: ...65E Turbo Motor Grader Service Manual Section 5 Front Axle Service 2 00_2013 03 5 x This page intentionally left blank ...
Страница 371: ...65E Turbo Motor Grader Service Manual Section 5 Front Axle Service 2 00_2013 03 5 30 This page intentionally left blank ...
Страница 381: ...65E Turbo Motor Grader Service Manual Section 5 Front Axle Service 2 00_2013 03 5 40 This page intentionally left blank ...
Страница 382: ...Service Manual Section 6 Rear Axle and Tandem Service 2 00_2013 03 ...
Страница 383: ......
Страница 456: ...Service Manual Section 7 Electrical Service 2 00_2013 03 ...
Страница 457: ......
Страница 465: ...65E Turbo Motor Grader Service Manual Section 7 Electrical Service 2 00_2013 03 7 x This page intentionally left blank ...
Страница 470: ...65E Turbo Motor Grader Service Manual 7 3 Service 2 00_2013 03 Section 7 Electrical TIER III ELECTRICAL SCHEMATICS ...
Страница 471: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 4 Section 7 Electrical ...
Страница 472: ...65E Turbo Motor Grader Service Manual 7 5 Service 2 00_2013 03 Section 7 Electrical ...
Страница 473: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 6 Section 7 Electrical ...
Страница 474: ...65E Turbo Motor Grader Service Manual 7 7 Service 2 00_2013 03 Section 7 Electrical ...
Страница 475: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 8 Section 7 Electrical ...
Страница 476: ...65E Turbo Motor Grader Service Manual 7 9 Service 2 00_2013 03 Section 7 Electrical TIER IVI ELECTRICAL SCHEMATIC ...
Страница 477: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 10 Section 7 Electrical ...
Страница 478: ...65E Turbo Motor Grader Service Manual 7 11 Service 2 00_2013 03 Section 7 Electrical ...
Страница 479: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 12 Section 7 Electrical ...
Страница 480: ...65E Turbo Motor Grader Service Manual 7 13 Service 2 00_2013 03 Section 7 Electrical ...
Страница 481: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 14 Section 7 Electrical ...
Страница 509: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 7 42 Section 7 Electrical 12 24 VOLT CONVERTER ...
Страница 518: ...65E Turbo Motor Grader Service Manual Section 7 Electrical Service 2 00_2013 03 This page intentionally left blank ...
Страница 519: ...Service Manual Section 8 Hydraulics Service 2 00_2013 03 ...
Страница 520: ......
Страница 528: ...65E Turbo Motor Grader Service Manual Section 8 Hydraulics Service 2 00_2013 03 8 x This page intentionally left blank ...
Страница 534: ...65E Turbo Motor Grader Service Manual Section 8 Hydraulics Service 2 00_2013 03 8 2 This page intentionally left blank ...
Страница 535: ...65E Turbo Motor Grader Service Manual 8 3 Service 2 00_2013 03 Section 8 Hydraulics TIER 3 HYDRAULIC SCHEMATIC ...
Страница 536: ...65E Turbo Motor Grader Service Manual Service 2 00_2013 03 8 3 Section 8 Hydraulics TIER 4I HYDRAULIC SCHEMATIC ...
Страница 627: ...OUT IN Eaton Gear Pumps No 6 623 Revised March 1993 PartsInformation Model 25500 Gear Pumps L2 Series ...
Страница 633: ...Char Lynn No 7 145 November 1996 Hydraulic Motor Repair Information TSeries General Purpose Geroler Motor 001 ...
Страница 641: ...Service Manual Section 9 Moldboard and Implement Service 2 00_2013 03 ...
Страница 642: ......
Страница 677: ...Service Manual Section 10 Diagnostic Fault Codes Service 2 00_2013 03 ...
Страница 678: ......