37
8 TROUBLESHOOTING
•
This section discusses common symptoms and suggested solutions when
the UC4+ control system is being installed or operated.
8.1 G
ENERAL
O
PERATION
8.1.1
•
LCD screen does not light up
•
System resets itself when a boom valve is turned on
Possible Cause(s)
Suggested Solution(s)
a)
Inadequate power
supply
NOTE:
If your system is operating below
+12 volts, this may cause a
problem. If you have a low
voltage problem, it could be due
to the sprayer’s electrical system
(e.g. faulty alternator, battery, or
poor ground connection).
a-1)
Ensure the UC4+ power cable is
connected to the UC4+ control panel.
a-2)
Ensure the UC4+ power cable is
connected to the sprayer’s power supply
properly.
a-3)
Ensure the sprayer’s power supply
voltage is high enough (more than +12V).
Measure the supply voltage when the
valve is being used, since the valve action
may cause a voltage drop.
b)
Defective power cable
b)
Follow a-1) to a-3). Wiggle cables/wires
around. If the symptom continues, the
cable may need repairing.
c)
Damaged LCD screen
c)
Follow a) and b). If the symptom
continues, the screen may need replacing.
8.1.2
•
Part of the LCD screen is black
•
Some of the digits do not appear on the LCD screen
•
LCD screen turns black (high contrast) temporarily
Possible Cause(s)
Suggested Solution(s)
a)
The control panel is
mounted so that direct
sunlight hits the front
panel (LCD screen)
a)
High temperature causes the LCD screen
to turn black (high contrast). This
symptom will disappear when the LCD
cools down.