32
6.3.4
Valve Gain Test
1.
Follow the steps,
6.1.1
to
6.1.3
(level booms, working RPM,
etc.), before proceeding.
2.
Ensure the UC4+ control panel is in
MANUAL
mode, at the
Normal Operating Screen.
3.
Navigate to the "
More ?
" menu prompt in the
SETUP
menu
Toggle the "
AUTO (YES)
" switch to confirm.
4.
Navigate to the boom section you wish to setup, for example
"
Right ?
" to adjust the right up and/or the right down
settings. Toggle the "
AUTO (YES)
" switch to confirm.
5.
Toggle the "
SETUP (NO)
" switch twice to access the right up
GAIN ("
-KP
Ç
") menu prompt.
6.
While viewing the GAIN ("
-KP
Ç
") menu prompt, perform one
of the two tests: AUTO GAIN Test or Manual GAIN Test.
NOTE: You do not need to run both the AUTO and Manual
tests. The tests are entirely independent.
a)
Auto Gain Test
•
Toggle and hold the "
AUTO (YES)
" switch.
•
When the "
Done
" message is displayed, release the
"
AUTO (YES)
" switch to view the new setting.
b)
Manual Gain Test
CAUTION!:
BEFORE CONTINUING MAKE SURE THE BOOM HAS
ROOM TO MOVE IN THE INDICATED DIRECTION AT
FULL SPEED FOR ONE SECOND. BE PARTICULARLY
CAREFUL IF YOU ARE WORKING WITH THE ROLL
CONTROL SECTION.
•
Toggle and hold the "
MANUAL
" switch.
•
The valve will turn on at 100 percent speed for exactly one-
second. The LCD screen will show the actual change in
height.
•
The change in height reading is live as long as you hold the
"
MANUAL
" switch. Wait until the height reading has
settled to a stable value and record this reading. This is your
boom speed in mm per second (mm/s) or inches per second
(in/s) if inches is the selected units.
•
Repeat the Manual Gain Test three times, repositioning the
boom as necessary.
•
Average your three readings. Typical values are between 15
and 50 inches/sec.