7
4 SYSTEM
OPERATION
This section outlines the UC4+ Spray Height Control system’s features and
controls during field operation. Before you can operate your UC4+ Spray
Height Control system in
AUTO
mode, it needs to be configured either
automatically or manually. If your control panel shows the power up
sequence below and will allow
AUTO
mode, it has been configured. If
your panel shows different messages after being powered up or will not
allow
AUTO
mode, it will attempt to begin or resume Automatic System
Setup. Refer to
Section 6
for System Setup instructions.
4.1 P
OWER
U
P
S
EQUENCE
The LCD screen messages shown below are displayed temporarily when
power is turned on to the UC4+ control panel. The system will always
power up in manual mode. Once the Normal Operating Screen is shown the
system is ready to use.
Table 1 – Power Up Screens
LCD Display
Description
UC4 +
UC4+ Control Panel
V. 6C
Version 6 software
Type AN2
Sprayer Type: AN2. See Sprayer Types
on page 54 – for a list of types.
METRIC
The panel is setup to display height in centimeters. This can
be changed to display inches.
* Nodes
The control panel is looking for connected sensors.
3 Height
Three height sensors are connected.
Allocate
The control panel is preparing to set up each sensor.
Setup LO
The control panel is setting up the Left outer (
LO
) sensor,
followed by the other sensors (
LI
,
RO
,
RI
,
MR
,
ML
).
Ready
The control panel is ready to begin operation
M 75 M
The Normal Operating Screen. This screen is shown until
input is received from the operator. (
Sec 4.2.1
)