8
4
INSTALLATION PROCEDURE
4.1
F
UNCTIONALITY CHECK
Before beginning the install, ensure all hydraulic
boom functions are operating properly on the
sprayer.
o
All Fold Functions
o
Main Lift Function
o
Wing Tilt Functions
o
Slant Function
4.2
E
XISTING SYSTEM CHECK
o
Inspect slide pads and wear surfaces for
excessive wear. Replace or adjust if
necessary.
o
Ensure the boom guide-rods are set to
the “tapered” position (factory setting)
o
Set boom suspension to be critically
damped (Figure 5). Adjust the boom
damper accordingly.
A)
Unlock the pendulum, and push
boom tip down approximately 75 cm
(30 inches).
B)
Hold the boom steady for a moment,
and release.
C)
Ensure the boom returns to its
relaxed state as quickly as possible,
with little to no overshoot.
Figure 5 –Boom Push Test- Critically
Damped
Содержание UC4+ Roll Control
Страница 11: ...7 Figure 4 Hydraulic Plumbing Schematic ...
Страница 40: ...36 6 3 ITEM C3 44656D CABLE VALVE VARIABLE RATE DT ...
Страница 41: ...37 6 4 ITEM C10 44658 52 CABLE UC4 BC POWER C10 HARDI ...
Страница 42: ...38 6 5 ITEM C11 44658 50 CABLE UC4 BC EXTENSION C11 HARDI ...
Страница 43: ...39 6 6 ITEM C12A 44658 51 CABLE UC4 BC INTERFACE HARDI DAH ...
Страница 44: ...40 6 7 ITEM C12 44658 78 CABLE UC4 BC INTERFACE HARDI DAH 09 ...