33
4.11
NORAC
VALVE AND SENSOR
CONNECTIONS
1.
Route the 6-pin shroud (
S6
) and 4-pin AMP
plug (
P4
) on C11 to the rear of the sprayer
near the sprayer valve block.
2.
Connect the 6-pin tower on the valve cable
(
C03
) to the mating 6-pin shroud (
S6
) on
C11 (
Figure 29
).
3.
Install the 2-pin connectors from C03 onto
each NORAC valve as shown in
Figure 38
.
4.
The connectors on the valve cable (
C03
)
are marked
RIGHT UP
,
LEFT UP
,
RIGHT DOWN
and
LEFT DOWN
.
Cables labeled with
UP
go on the same side
as the hydraulic hoses.
Figure 38 – Valve Cable Connections
5.
Connect the sensors (
E02
) to the 4-pin
AMP connectors on cable C02.
6.
Connect the roll sensors (
E03
&
E04
) to
the 4-pin AMP connectors on cable C02A.
For details on mounting the UC4
Control Panel (Item E01) and
necessary electrical connections inside
the cab, refer to the UC4-BC-HD4E
End-User document.
Содержание UC4+ Roll Control
Страница 11: ...7 Figure 4 Hydraulic Plumbing Schematic ...
Страница 40: ...36 6 3 ITEM C3 44656D CABLE VALVE VARIABLE RATE DT ...
Страница 41: ...37 6 4 ITEM C10 44658 52 CABLE UC4 BC POWER C10 HARDI ...
Страница 42: ...38 6 5 ITEM C11 44658 50 CABLE UC4 BC EXTENSION C11 HARDI ...
Страница 43: ...39 6 6 ITEM C12A 44658 51 CABLE UC4 BC INTERFACE HARDI DAH ...
Страница 44: ...40 6 7 ITEM C12 44658 78 CABLE UC4 BC INTERFACE HARDI DAH 09 ...