-14-
START-S19
Operating guide
S 01
01
02
03
04
05
06
COLLECTIVE USE + DEAD’S MAN
SAME S01 - 2 with OPEN AND CLOSE
wtih DEAD’S MAN function
RAPID REVERSING MOTOR
Ech command START reverse:
open-close
Automatic reclosing
COLLECTIVE USE
START command can open or recharge the pause time
Automatic reclosing
BISTABLE
EACH START follows the logic
open-stop-close-stop-open...
No automatic reclosing
BISTALBE WITH RECLOSING AFTER THE PAUSE
Each START follows the logic
Open-stop-close-stop-open...
Automatic reclosing
RAPID REV DEAD’S MAN FUNCTION
SAME AS S01 - 1, with OPEN AND CLOSE
wtih DEAD’S MAN function
4
FUNCTIONS and ADJUSTMENT
4.1
Logic of functions
07
08
BISTABLE WITH REC DEAD’S MAN FUNCTION
Same as S01 - 4, with OPEN AND CLOSE
with DEAD’S MAN function
BI DEAD’S MAN
Same S01 - 3, with OPEN AND CLOSE
wtih DEAD’S MAN function
S 02
RECLOSING AT THE RESWITCHING
Makes a complete cycle pause and close,
ONLY IN FAIL POWER and the door was open
.
01
S 04
IT DETECTS THE PASSAGE
The access will be detected from the photo-beams, if
S07
is
0
the pause time is 2sec.
01
S 07
IT REVERSE IN CASE OF ACCESS
Put
S04
in
1
. When the gate is opening, the control unit
inverts the direction and close
01
S 08
LOGIC OF INTERVENTION OF THE OBSTACLE DETECTION
1 - Considered as Limit Swith
2 - Considered as STOP