-7-
START-S19
Operating guide
1.13 Connection of the PHOTOCELLS (ONLY CLOSE)
24 Vac
RX
TX
NC Contact
No TEST
With TEST
24 Vac
The contact of the receiver
should be:
- Dry
(isolated from
tensions)
- Normally closed
If the input PHOTO
is not used, set S16 in 0
!
6 7 8 9 10 11 12 13 14 15 16 17
41 42 43 44 45 46 47 48 49
S 16
Input PHOTO
1- Activated
0 - Deactivated
6 7 8 9 10 11 12 13 14 15 16 17
38 39 40 41 42 43 44 45 46 47 48 49
RX
TX
NC Contact
24 Vac
The TEST of the photo-beam works only if the photo-beams are installed properly. The control unit will check all
connections before opening!
In case the photo-beam are not working properlym the control unit will lit on for 5 seconds and the gate is not mo-
ving.
To activate the
TEST
set
1
in the
PHOTO-A:
If you need to bring back the photocells with NO TEST, connect the photocells and bring at 0 S06 and S09
(deacti-
vate this function only if other inputs are under TEST).
S 09
Activated TEST in the PHOTO INPUT
1- Activated
0 - Deactivated
S 06
TEST in the INPUT
SAFETIES
1- Activated
0 - Deactivated