-5-
START-S19
Operating guide
1.7
Connection of the LSC and LSC
In the picture you can see the connection of both limit switches but in
the control panel you can use separatelly. THE CONTACTS OF THE LS
SHOULD BE N.C.
If the LSO and LSC inputs are not used
Set up S13-S14 as shown:
!
6 7 8 9 10 11 12 13 14 15 16 17
APRE
N.C.
CHIUDE
N.C.
CONTATTI
FINECORSA
S 13
S 14
Input LSO
1- Activated
0 - Deactivated
Input LSC
1- Activated
0 - Deactivated
1.8
Power supply for ACCESSORIES
38 39 40 41 42 43 44 45 46 47 48 49
Terminals 48 (+) / 49 (-)
Power:
12 Vdc
MAX Absorption:
50 mA
Terminals 47 (+) / 49 (-)
Power:
24 Vdc
MAX Absorption:
50 mA
+
-
-
+
Terminals 44 / 45
Power:
24 Vac
MAX Absorption:
300 mA
Terminals 44 / 46
Power:
12 Vac
MAX Absorption:
300 mA
1.6
Connection of a 24V light For open or moving gate
44 45 46 47 48 49
38 39 40
+
-
If you use the test for the photoeyes
or a signal light, you cannot do this connection
!