84
SS300 Service Information (3-2017)
SERVICE
REMOVING SCRUB HEAD ASSEMBLY
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off machine,
remove key and disconnect batteries.
1. Drain recovery tank, turn off key, and disconnect
batteries.
2. Remove debris tray (cylindrical only).
3. Remove scrub brushes and set aside.
4.
Lower scrub head to floor.
5. Remove front shroud mounting hardware (2).
6. Pull forward to remove shroud. Set shroud aside.
7. Disconnect motor from wire harness connection.