SS300 Service Information (3-2017)
89
SERVICE
INSTALLING LOWER ORBITAL HEAD ISOLATOR
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off machine,
remove key and disconnect batteries.
1. Installation is the reverse of removal.
2. During reassembly, place a 30 lb weight on the
top of the motor while tightening the motor shaft
set screw. This weight simulates the actual down
force on the scrub head and sets the shaft pre-
load. Torque the set screw to 15 ft-lbs (20 Nm).
30 lbs.
Set Screw
REMOVING TRANSAXLE ASSEMBLY (OPTION)
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off machine,
remove key and disconnect batteries.
1. Drain solution and recovery tanks.
2. Disconnect batteries.
3. Remove batteries and set aside.