34
SS300 Service Information (3-2017)
MAINTENANCE
3. Disconnect the two hose connectors from the top
of the cartridge by pressing the gray collars inward
and pulling the connectors outward (Fig. 118). Lift
cartridge to remove.
Gray
Collar
Fig. 118
4. Fill in the installation date on the new cartridge
label (Fig. 119).
Fig. 119
5. Install the new cartridge and reconnect the two
hoses. Make sure the hose connectors are fully
inserted into the cartridge.
6. Reset timer for new cartridge.
Carefully read and understand all steps first before
performing procedure.
A. Turn key on.
B. Press and hold the service switch, located on the
ec-H2O module, for 10 seconds. After releasing
service switch, the three solution flow indicator
lights will begin to (ripple) move back and forth
(Figure 129).
C. Within 5 seconds after releasing the service
switch, while the three indicator lights are moving
back and forth, quickly press and release the
solution flow button located on ec-H2O module
(Fig. 120). The three indicator lights will then
blink three times to indicate timer has been reset.
Repeat process if the three
Service switch
3 indicator lights
Solution flow button
Fig. 120
LOADING/UNLOADING MACHINE FOR
TRANSPORTING
When transporting the machine by use of trailer or
truck, carefully follow the loading and tie-down proce-
dure:
1. Raise the scrub head and remove squeegee
assembly.
2. Use a ramp that can support the machine weight
and operator and carefully load machine. Do
not operate the machine on a ramp incline that
exceeds a 21% grade level (Fig. 121). A winch
must be used when ramp incline exceeds a 21%
grade level.