64
SS300 Service Information (3-2017)
TROUBLESHOOTING
SOLUTION CONTROL ON (CONVENTIONAL)
Operator’s Switch/LED
Touch Panel
(2) 12 VDC Batteries
1/RED
13/BLK
13/BLK
5/GRN
6/BLU
54/YEL
30/TAN
31/PNK
6/BL
U
6/BLU
+
-
+
-
12 Volt
12 Volt
Key
Switch
Battery Po
Battery Negative -
PMC021
Bail Switch (N.O)
Bail Switch Harness
P2-2 Onboar
d
Char
ger or I
nter
-
lock S
wit
ch N.C.
Circuit Breaker 1
Interface Module
J7-10 KSI (KEY SWITCH
INTERLOCK)
J7-7 FLYBACK
J7-5 SOLUTION VALVE OUT
GND J7-8
SENSOR_IN J4-4
+5V OUT J4-1
SV1 Solution
Valve
Solution
Control
(Conventional)
Enabled
• Head Lowered -
Foot Pedal
• Solution Control ON
• Fwd/Rev Throttle
Command or Bail
activated on non-
propel models.
Disabled
Operational Matrix:
• Head Raised - Foot Pedal
• Solution Control OFF
• Neutral - Ready State or bail
released on non-propel models.
• Low Battery Voltage
• Fault
• Battery Charger ON Interlock