100
SS300 Service Information (3-2017)
SERVICE
7. Remove the heat sink and machine control
module assembly from the scrubber.
INSTALLING CONTROL MODULE
FOR SAFETY: When servicing machine,
disconnect battery connections before working
on machine.
1. Attach a static wrist strap to the battery (-)
terminal to prevent ESD damage to the logic
board.
2. Installation is reverse of removal.
NOTE: The torque specification for control module
electrical cables is 52 in-lbs (6 Nm).
REMOVING i-DRIVE MODULE (OPTION)
FOR SAFETY: When servicing machine,
disconnect battery connections before working
on machine.
1. Key Off and batteries disconnected.
2. Remove T-25 torx mounting screws (2).
3. Carefully lower access cover.
4. Remove four (4) hex screws to remove the
control consol plate.