SS300 Service Information (3-2017)
105
SERVICE
8. Remove operator console mounting bolts (2).
9.
Lift up and forward to remove the operator
console and place console on a work bench.
10.
Remove plastic knobs and set aside. If replacing
the potentiometer or directional switch, use
a socket to remove the nut securing the
potentiometer or the directional switch.
11. Remove bail screws (2) and set bail aside.
12. Remove screws (4) from front of operator’s
console.
13. Remove screws (9) from rear of operator’s
console and separate console assembly.