Nivis Versa Router 1100 Titan - User Guide
v1.2
Page 14 of 111
9.
Configure the SIM card
below)
10.
Unwrap the battery positive connector can connect it to the battery positive terminal.
This action will start up on the Titan and power on the RF amplifier
; several LED’s on the Titan board
will light up as well as a LED on the RF amplifier. At this point Titan draws power from the battery.
11.
Connect the power cable to the mains (110 VAC) then switch the circuit breakers into “ON” position. At
this point Titan draws power from the mains, and the battery gets charged from the mains.
12.
Titan is fully powered on now
.
NOTE
Titan is delivered without a mains power plug/power connector, as the method to connect to the
mains depend on the local conditions and the utility. The utility should use an appropriate connection
cord and connection solution to the mains find appropriate, with the restriction that the power cable
diameter must not exceed
6.5 mm / 0.256 inch
– that is the inner diameter of the power cable gland.
NOTE
Any mechanical operation involving Titan SIM card, SD-card, RF/Cell Antennae, ETH cable must be
performed with Titan
fully powered off
(Titan disconnected from mains
and
battery positive connector
disconnected from battery)