Nivis Versa Router 1100 Titan - User Guide
v1.2
Page 13 of 111
4.
Pass the power cable (max 6.5 mm / 0.256 inch) through one of the cable glands (recommend the one
farthest to the circuit breakers, as it makes connecting the power easier)
5.
Make sure the power cable is not connected to the mains at this point!
6.
Connect the power cable PE/L/N wires as indicated in the label below the connectors
7.
Optional
while in the lab but mandatory at deployment: unwrap the RF antenna and mount it on top of
the enclosure.
8.
Optional
, if necessary: connect the ETH connector to Titan. This option is available only in the laboratory
as it will keep the enclosure lid open; there is no provision to take the ETH cable out of the enclosure
with the lid closed.
Optional
while in the lab but mandatory at deployment: install an standard format SIM card (active, with data
plan associated, details in the section
Connector
for 110V AC
Power cable
gland
N
L
PE