FORM NO. 56043052 / HYDRO-RETRIEVER™ 2052, CR 1300 - 59
HYDRO-MAX
™
II SYSTEM
FUNCTIONAL OVERVIEW
The optional Hydro-Max
™
II system extends the solution’s useful capacity (conserves water usage) by recycling the wastewater picked up from
the floor. This allows the machine to scrub continuously, saving time in emptying the recovery tank and refilling the solution tank. The wastewater
entering the recovery tank passes through special baffles and filters to remove most of the dirt, then new soap is injected into the treated solution
as it is pumped back into the solution tank.
The system operates electrically by closing the Hydro-Max
™
II recycling ON/OFF switch (S8) located on the dash panel. Note: Reference the
machine Operator Manual for exact system operation steps. With solution usage and wastewater recovery the pump is started when the two
mercury switches (S17 start and S18 stop) mounted on float Arm (A) are closed (see Figure 2). The solution tank stop switch (S16) is normally
closed, should the solution tank become over filled this switch will open and not allow the pump to run.
The specific functional operation of the mercury switches S17 & S18 start out both open. This is caused by the switch arm float not being activated
the recovery tank is empty (dry). With the system prepared for use (see Operator Manual to operate the Hydro-Max
™
II system) the recovery
tank is filled with clean water when starting Hydro-Max
™
II use. When scrubbing, the wastewater is picked-up and the water level and float both
rise. The float switches are mounted at two different angles and the S18 (stop) switch closes first then with additional water level increase the
S17 (start) switch closes and the K4 pump relay is energized and the pump motor starts. The pump will run continuously within a range set between
the difference of the water level and float angle.
Notes: * H2 shown in the diagram is the low solution chemical tank indicator light. ** S15 is the detergent tank level float switch.
Hydro-Max
™
II Wiring Diagram
revised 3/00
( )
In Recovery
Tank
N.C.
Dry
In Solution
Tank
( )
N.O.
Dry
S17
N.O.
Dry
RED
BLK
Pump Motor
M2
(
)
H2
S8
K4
F4
+
36V
K4
S15
BLU
S18
S16
_