![Nilfisk-Advance Hydro-Retriever 2052 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/nilfisk-advance/hydro-retriever-2052/hydro-retriever-2052_service-manual_1693280022.webp)
20 - FORM NO. 56043052 / HYDRO-RETRIEVER™ 2052, CR 1300
SCRUB BRUSH SYSTEM
SYMPTOM TWO
Part B: Scrub Brush Motor Control Circuit Troubleshooting Guide
revised 3/00
Check for 36V at
the K5 solenoid
coil wires
Wht
/Gra &
Blu/Red
Scrub brushes
do not turn (see
Figure 3).
Replace the
K5 Brush
Motor Solenoid
Yes
Check for 36V at
the Pos.
K5 coil
wire Blu/Red to
a Neg. battery
standoff
No
Check for 36V
at the Neg.
K5
coil wire
Wht
/Gra to a
positive battery
standoff
Yes
Check for 36V at
the Org
/Grn wire
on the S7 brush
switch
Check for 36V at
the blue wire on
the S7 brush
switch
Check for correct
wiring & repair or
replace
No
Replace the S7
brush switch
Yes
No
No
Check for 36V (Pos.) at the timer
input #1 on the E1 brush lift actuator
control. Note: The Fwd drive pedal
switch S3 must be closed. Repeat
this check at the timer #2 for the Rev
switch S1.
Check function of
K9 coil & con-
tacts. Repair or
replace.
Replace the E1
brush lift
actuator control
board
Yes
No
Yes
Check Seat Switch
and wiring repair
or replace.
No
TROUBLESHOOTING GUIDE (CONTINUED)