18 - FORM NO. 56043052 / HYDRO-RETRIEVER™ 2052, CR 1300
SCRUB BRUSH SYSTEM
Check the battery
meter. Is it double
flashing
Check for 36V (pos.) at
both the Red & Org input
wires on the K8 module
Recharge battery
pack (the low voltage
cut out is functioning).
Brush / Brush Lift /
Broom / Solution
Systems; do not
work (See Fig.4)
Check the function of
the S4 Key Switch
and S13 Seat Switch
repair or replace.
Check for 36V at both
the Yel & Blk output
wires on the K8 module
Replace the K8
low voltage cut
out module
Check continuity on the
F8 fuse (1.5A)*
Replace the F8
(1.5A) fuse
Check for 36V at
the A& B (K9) coil
relay terminals
Replace the K9
low voltage cut
out relay
Locate the open in
the K9 coil relay
wiring and repair
No
Yes
Yes
No
No
Yes
No
Yes
No
Yes
TROUBLESHOOTING GUIDE
Possible Symptoms
1
Brush / Brush Lift / Broom / Solution; do not work
2
Scrub brushes do not turn
3
Scrub brushes do not lower
4
Scrub brushes do not raise
SYMPTOM ONE
Note: Do all testing with the master key switch ON, seat switch S13 closed, brush switch S7 in the ON position and the parking brake set.
revised 3/00
*Note: Some of the early Hydro-Retriever
™
2052 machines do not use the F8 Fuse.