FORM NO. 56043052 / HYDRO-RETRIEVER™ 2052, CR 1300 - 61
HYDRO-MAX
™
II SYSTEM
HYDRO-MAX
™
II RECOVERY TANK MAINTENANCE
IMPORTANT!
The recovery tank should be cleaned after each use, in order for Hydro-Max
™
II system to operate properly.
To clean the tank…
1
See Figure 3. Use the two Drain Hoses (B) to drain both the recovery tank compartments (one on each side of the tank).
2
Lift out the removable Screen Panel (C) and rinse under running water.
3
Rinse the pump pick up strainer Screen (D) thoroughly (located on the right side of the tank).
4
Remove the two clean-out Doors (E) from the back of the tank. Scoop out any built up sludge and flush the bottom of the tank.
5
Then reinstall the clean-out doors and the screen panel.
SOLUTION DETERGENT TANK MAINTENANCE
1
Remove the metering barb from the detergent hose and elbow mount then soak the barb in hot water to loosen chemical build up. For
stubborn cleanup soak the barb in a light muriatic acid solution and use a pin to clean hardened chemical from the hole. Note use caution
when working with acid wear safety glasses and gloves.
2
Clean the detergent storage tank by flushing the detergent tank with clean water to remove built up debris. Service Tip: Attach a piece
of hose to the tank outlet elbow with the metering barb removed to help drain contents into container.
HYDRO-MAX
™
II SYSTEM TROUBLESHOOTING
Problem
Possible Cause
Water does not transfer from the
Clogged pump pick up filter
recovery tank to the solution tank
Defective pump float switches
Defective switch in solution tank
Defective solution pump
Vacuum shut off float closes prematurely
Picking up water from a source other than machine
Clogged pump pick up filter
Solution chemical not injected
Clogged metering barb
Stuck check valve in chemical injector
Air leak in chemical hose
revised 3/00