28 - FORM NO. 56043052 / HYDRO-RETRIEVER™ 2052, CR 1300
SWEEPING SYSTEM
TROUBLESHOOTING GUIDE
Possible Symptoms
1
Broom motor will not run
2
Broom side skirts will not lower
3
Broom side skirts will not raise
SYMPTOM ONE
Note: Do all testing with the master key switch ON, seat switch closed, broom lever in the ON position and the parking brake set.
Part A: Sweeping Broom Motor Load Circuit Troubleshooting Guide
revised 3/00
Broom motor does
not run (see Fig. 1).
Check continuity on the
F3 (40A) broom motor
circuit breaker
Reset or replace the
F3 (40A) broom motor
circuit breaker
At the K6 broom motor
solenoid Check for
36V at the wht/vio wire
to negative battery
standoff
Check for 36V at the
M1 broom motor
See part B sweeping
broom control circuit
troubleshooting
Repair or replace the
M1 broom motor
Yes
No
No
Yes
Yes
Repair or
replace wiring.
No