22 - FORM NO. 56043052 / HYDRO-RETRIEVER™ 2052, CR 1300
SCRUB BRUSH SYSTEM
SYMPTOM FOUR
Note: Do all testing with the master key switch OFF, brush switch S7 in the ON position and the parking brake set.
revised 3/00
TROUBLESHOOTING GUIDE (CONTINUED)
No
Yes
Yes
No
No
Yes
No
Yes
Scrub brushes do not
raise (see Fig. 4)
Check for 36V at the
M3 lift motor harness
connection
Replace the
M3 lift motor
Check for continuity
through the S10 UP
limit switch
Replace the S10
UP limit switch
Back probe the
blu/red direction
input wire on the E1
controller, should
read zero V
Check for 36V at the
motor power output
GRN/BLK (neg.) &
VIO/BLK (pos.) on
the E1 controller
Check function of
K9 coil & contacts.
Repair wiring or
replace.
Replace the E1
controller
Repair wiring and
connections to the
M3 lift motor