FORM NO. 56043052 / HYDRO-RETRIEVER™ 2052, CR 1300 - 39
SOLUTION SYSTEM
+
M
B+
B-
Motor+
Motor-
Direction
Timer Out
Timer In 1
Timer In 2
S4
K9
S7
E1
S10
S11
M3
_
L1
K5
+
S3
S1
S19
D5
M
M4
S13
Seat Switch
FUNCTIONAL OVERVIEW
Functional Overview Standard Solution System:
A 60-gallon (227 L) capacity solution tank is located to the left of the operator’s compartment. Plumbed to it is an externally mounted serviceable
solution filter, to help keep dirt out of the solution valves. The tank is also fitted with a flexible drain hose to facilitate quick draining for system
maintenance.
The solution system uses (4) valves to regulate the amount of solution dispensed onto the floor. See Figure 2 showing the valve layout. A lever
located on the control panel operates the main (master) flow valve; its function is to control the water volume to the (2) individual scrub brush final
control valves. The electrical solenoid valve (L1) and dash mounted solution switch (S19) start and stop the solution flow. The (S19) solution ON/
OFF switch when ON works in-conjunction with the drive pedal switch that controls the timer input to the E1 controller that energize the (L1) solution
solenoid valve. The solution will flow to the scrub brushes any time the drive pedal is depressed (FWD/REV). Note: When the solution on/off switch
(S19) is turned off, no flow can occur regardless of the other valves being on or the drive pedal position.
Explanation of the Solenoid Valve Function
See Figure 1. To energize the L1 solution solenoid the S7 brush switch must be on (brushes lowered) and the K9 relay contacts closed. This
completes the positive voltage input to the solenoid. The negative voltage input to the solenoid is supplied when the drive pedal is depressed
(FWD or REV). This closes either the S3 or S1 directional switches that triggers the E1 control module’s timer inputs that close the negative timer
output connection. This completes the L1 solution solenoid circuit and the valve is open (ON). Note: The timer output voltage from E1 will remain
closed for 3 seconds after the drive pedal is returned to neutral. Then the output circuit is open and the brushes and solution will stop. This feature
eliminates the nuisance stopping and starting of both systems when the machine changes direction.
Solution System Electrical Diagram
revised 3/00
FIGURE 1