Code#
Fault Description
Correction
05 C
2200 RPM no input @ ECM
Check for 12V (+) from controller wire J2-29 (GRA/ORN) to
battery ground (-) with the engine speed switch 51 active.
Should read 12V.
If 0V, troubleshoot the throttle wire. If still 0V, substitute a
good known controller and dashboard panel.
If 12V and no 2200 RPM throttle response, test engine
FRQWUROOHURXWSXWWRVSHFL¿FWKURWWOHFRQWURO*/3'6HH
engine wiring diagram for additional help.
06 NC
2400 RPM no input @ ECM
Check for 12V (+) from controller wire J2-30 (GRA/BLU) to
battery ground (-) with the engine speed switch 51 active.
Should read 12V.
If 0V, troubleshoot the throttle wire. If still 0V, substitute a
good known controller and dashboard panel.
If 12V and no 2400 RPM throttle response test engine
FRQWUROOHURXWSXWWRVSHFL¿FWKURWWOHFRQWURO*/3'
07 NC
Main solution solenoid valve
over current
Check L10 solenoid coil wiring for problems (+ ORN and -
YEL/GRN).
Check coil resistance. If less than 6 ohms, replace. Also
see main scrub and right side scrub solution valves and
pump electrical ladder detail.
08 NC
Right side scrub solution
solenoid valve over current
Check L11 solenoid coil wiring for problems (+ ORN and -
BLU/YEL).
Check coil resistance. If less than 10 ohms, replace. Also
see main scrub and right side scrub solution valves and
pump electrical ladder detail.
09 C
Vacuum fan solenoid over
current
Check L1 solenoid coil wiring for problems (+ GRN/BRN
and - BRN/YEL).
Check coil resistance. If less than 6 ohms, replace. Also
see vacuum fan on and squeegee down electrical ladder
detail.
10
Not used
11 C
Squeegee UP solenoid over
current
Check L3 solenoid coil wiring for problems (+ GRN/BRN
and - BRN/GRN).
Check coil resistance. If less than 6 ohms, replace. Also
see vacuum fan off and squeegee up electrical ladder
detail.
12 C
Squeegee DN solenoid over
current
Check L2 solenoid coil wiring for problems (+ GRN/BRN
and - RED/GRA).
Check coil resistance. If less than 6 ohms, replace. Also
see vacuum fan on and squeegee down electrical ladder
detail.
13 C
Scrub brush motor solenoid over
current
Check L4 solenoid coil wiring for problems (+ ORN and -
ORN/BLU).
Check coil resistance. If less than 6 ohms, replace. Also
see main scrub on and side sweep/right scrub electrical
ladder detail.
Содержание Condor XL
Страница 15: ...General Information 6HUYLFH 0DQXDO GYDQFH RQGRU 1LO VN 5 2YHUDOO LPHQVLRQV ...
Страница 85: ...HULDO QXPEHU ...
Страница 86: ...HULDO QXPEHU ...
Страница 105: ... QJLQH 6 VWHP DVROLQH 3 6HUYLFH 0DQXDO GYDQFH RQGRU 1LO VN 5 QJLQH XVH R LULQJ 2UGHU ...
Страница 119: ... GUDXOLF 6 VWHP 119 6HUYLFH 0DQXDO GYDQFH RQGRU 1LO VN 5 GUDXOLF 6FKHPDWLF ...