6ZHHS6\VWHP6LGH%URRP
6HUYLFH0DQXDO±$GYDQFH&RQGRU;/1LO¿VN(5
The
Right Side Scrub/Sweep Solenoid Valve
S8/L8
controls the side sweep motor(s).
S8/
L8
is located above the front end of the
Scrub Deck
.
0DLQWHQDQFHDQG$GMXVWPHQWV
:DUQLQJ %HIRUHSHUIRUPLQJDQ\PDFKLQHPDLQWHQDQFHRUDGMXVWPHQWVPDNHVXUHWKHNH\
VZLWFKLVRIIWKHNH\LVUHPRYHGIURPWKHPDFKLQHDQGWKHSDUNLQJEUDNHLVHQJDJHG
7R$GMXVWWKH6LGH%URRP/LIW$FWXDWRU0RWRU
1. Assemble the jumper wire that you’ll
need to connect machine battery
to the three-wire connector on the
actuator. Refer to the adjacent
Jumper
Wire Assembly
Schematic
and
Bill of
Material
.
Important Service Note:
The power cord adapter (p/n
56407502), normally used on all
other two-wire actuator motors,
should not be used on the side
broom lift actuator motor.
The
Jumper Wire Assembly
Schematic
illustrates the correct battery polarity
(+ and -) power inputs to operate the
actuator motor for both extending and
retracting the drive nut.
Scrub
Deck
S8/L8
Jumper Wire Assembly Schematic