&RQWURO6\VWHP
43
6HUYLFH0DQXDO±$GYDQFH&RQGRU;/1LO¿VN(5
&RQWURO%RDUG'ULYHU%R[3URJUDPPLQJ2SWLRQV
)RRW3HGDO1HXWUDO3RVLWLRQDQG'HDGEDQG$GMXVWPHQW
Factory Default: 3%
Range: 2% - 15%
Whenever you change or repair the drive pedal linkage components or the hydrostatic unit, or if you replace
the Rotary Sensor or Control Board (Driver Box), you will have to recalibrate the neutral deadband position
and set the sensitivity as follows:
1. Depress the foot pedal to the full reverse position, then allow the pedal to slowly return to its neutral
position. Do not move the pedal during the remainder of this procedure.
2. Press and hold the Engine Speed switch, then turn the ignition Key Switch to the run (on)
position. Continue to hold the Engine Speed switch until all the display panel lights turn off
(approximately three seconds), then release the switch.
7KHÀUVWOLQHRIWKH/&'ZLOOUHDG
PEDAL CALIBRATION
.
The second line of the display will read
Place Pedal in Neutral
with an arrow to the left of
the line.
The third line of the display will read
Neutral Deadband
.
3. Press the green Scrub On switch.
7KHÀUVWOLQHRIWKH/&'
will read
Neutral Set
.
The second line of the display will show the resistance value, in ohms, that the control
board is reading through the rotary sensor. Note that it’s normal for this value to drift a
little.
4. Press the green Scrub On switch to set the nominal deadband resistance value. The display will return
to the previous menu.
5. Press the Side Broom Down (
-
) switch to move the arrow to the left of the
Neutral
Deadband
line.
6. Press the green Scrub On switch to display the
Neutral Deadband
range menu. The
percentages shown are the limits the resistance from the rotary sensor can vary from
the
Neutral Set
(nominal) resistance and still be in the deadband range and allow the
engine to start.
7. Press the Side Broom Up (
+
) and Down (
-
) switches to scroll through the available
percentages.
Note:
The ideal neutral deadband percentage range is one that allows reliable
starting, yet still actuates the scrub functions with minimal pedal travel.
The factory default value is 3%.
8. When the arrow is to the left of the desired percentage value:
Press the green Scrub On switch to save the new percentage value. The display will
return to the previous menu.
Содержание Condor XL
Страница 15: ...General Information 6HUYLFH 0DQXDO GYDQFH RQGRU 1LO VN 5 2YHUDOO LPHQVLRQV ...
Страница 85: ...HULDO QXPEHU ...
Страница 86: ...HULDO QXPEHU ...
Страница 105: ... QJLQH 6 VWHP DVROLQH 3 6HUYLFH 0DQXDO GYDQFH RQGRU 1LO VN 5 QJLQH XVH R LULQJ 2UGHU ...
Страница 119: ... GUDXOLF 6 VWHP 119 6HUYLFH 0DQXDO GYDQFH RQGRU 1LO VN 5 GUDXOLF 6FKHPDWLF ...