Problem
Cause
Correction
No solution to the
main brushes
No voltage to the main
solution pump
1. Check the wiring and circuit breakers upstream of
the pump.
2. Check the J3-2 output from the Driver Box.
Solution pump(s) over
current (fault code 00
displayed)
Check the M4 main solution pump wiring for
problems; M4 wire colors (+GRN/BRN and - GRN/
BLU).
Check the pump current draw (11.5 amps max.)
and replace as necessary.
Check pump motor for short circuits and replace
as necessary.
Main solution solenoid valve
over current (fault code 07
displayed)
Check L10 solenoid coil wiring for problems
(+ ORN and - YEL/GRN).
Check coil resistance. If less than 6 ohms, replace.
The solution shutoff valve is
plugged or inoperative.
Clean or replace the solution shutoff valve.
Inadequate solution
ÀRZWRWKHPDLQ
brushes
7KHVROXWLRQ¿OWHUVFUHHQLV
plugged.
&OHDQWKHVROXWLRQ¿OWHUVFUHHQ
Plugged solution hose
Check and clear the solution hoses as necessary.
No solution to the
DustGuard
™
spray
nozzles
Side sweep mist pump
over current (fault code 04
displayed)
Check Pump motor M5 wiring for problems (+ BLU
and - YEL/BLK).
Check the mist pump current draw (3.9 amps max.
at full load). Note: The mist pump is a 24V pump
operating at 12V.
No voltage to the mist pump
1. Check the wiring and circuit breakers upstream of
the pump.
2. Check the J3-18 output from the Driver Box.
Spray nozzles plugged
Clean the spray nozzles.
Содержание Condor XL
Страница 15: ...General Information 6HUYLFH 0DQXDO GYDQFH RQGRU 1LO VN 5 2YHUDOO LPHQVLRQV ...
Страница 85: ...HULDO QXPEHU ...
Страница 86: ...HULDO QXPEHU ...
Страница 105: ... QJLQH 6 VWHP DVROLQH 3 6HUYLFH 0DQXDO GYDQFH RQGRU 1LO VN 5 QJLQH XVH R LULQJ 2UGHU ...
Страница 119: ... GUDXOLF 6 VWHP 119 6HUYLFH 0DQXDO GYDQFH RQGRU 1LO VN 5 GUDXOLF 6FKHPDWLF ...