70 - FORM NO. 56043097 / Adgressor
™
/ BR 850S, 850CS, 950S, 950CS, 1050S, 1050CS
ELECTRICAL SYSTEM
Single or Dual Vacuum Motor Selection:
FACTORY DEFAULT: 1 (SINGLE VACUUM MOTOR)
The Adgressor/BR 850S and 850CS comes with a standard single vacuum motor. A dual vacuum motor option is available. The control unit must
be programmed for the number of vacuum motors installed to provide the proper overload protection. To program the control for the number of
vacuum motors perform the following steps:
1 Turn the main power key switch to the off position.
2 Press and hold the scrub system off and vacuum switches.
3 While holding both switches turn the main power key switch to the on position.
4 Continue to hold both switches until the vacuum indicator is yellow.
5 Release both switches. The status display will now indicate “1” or “2”.
6 Pressing and releasing the vacuum switch will now select between “1” for a single vacuum motor or “2” for dual vacuum motors.
7 To save the new setting turn the main power key switch to the off position.
8 The new setting will be saved and will remain in effect until it is changed again.
Control Unit Sleep Delay Period:
FACTORY DEFAULT: 1 (10 MINUTES)
If the Adgressor/BR 850S and 850CS are left in an idle state for a period determined by the sleep delay setting the control unit will automatically raise
the scrub deck, raise the squeegee, and turn off any accessories. This is to conserve battery power. The sleep period is adjustable from 10 to 90
minutes in 10 minute increments. It can also be turned off. To change the sleep delay period perform the following steps:
1 Turn the main power key switch to the off position.
2 Press and hold the scrub system off and the wand switch.
3 While holding both switches turn the main power key switch to the on position.
4 Continue to hold both switches until the wand indicator is fl ashing.
5 Release both switches. The status display will now indicate a number from 0 to 9 depending on the current sleep delay period.
6 Pressing and releasing the wand switch will now select the delay period. The level will increment from 0 to 9; 0 = off (sleep disabled), 1 = 10
minutes, 2 = 20 minutes, ... up to 9 = 90 minutes.
7 To save the new setting turn the main power key switch to the off position.
8 The new setting will be saved and will remain in effect until it is changed again.
Squeegee Raise-In-Reverse Time Period Adjustment:
FACTORY DEFAULT: 5 (2.0 SECONDS)
When backing up with the recovery system active, the control unit will automatically raise the squeegee just enough to prevent dragging on the fl oor.
The time that the squeegee is raised is adjustable from 1 to 4.8 seconds in .2 second increments. To adjust the distance the squeegee is raised in
reverse perform the following steps:
1 Turn
the
main power key switch to the off position.
2 Press and hold the scrub pressure decrease and the vacuum switch.
3 While holding both switches turn the main power key switch to the on position.
4 Continue to hold both switches until the vacuum indicator is fl ashing yellow.
5 Release both switches. The status display will now indicate a number from 0 to 19 depending on the current time period. NOTE: If the decimal
point is not illuminated the display is indicating 0 – 9. If the decimal point is illuminated the display is indicating 10 – 19.
6
Pressing and releasing the vacuum switch will now select the time period. The level will increment from 0 to 19. 0 = 1 second, 1 = 1.2 seconds,
2 = 1.4 seconds, ... up to 19 = 4.8 seconds.
7 To save the new setting, turn the main power key switch to the off position.
8 The new setting will be saved and will remain in effect until it is changed again.
SPECIAL PROGRAM OPTIONS (CONTINUED)