12 - FORM NO. 56043097 / Adgressor
™
/ BR 850S, 850CS, 950S, 950CS, 1050S, 1050CS
Fixed Pressure Mode
Scrub System Off Switch - Pressing this switch when the scrub system is active will cause the following to occur:
•
The scrub brushes will turn off and the scrub deck will raise to the up position
• The
solution
fl ow will be stopped
• The
fi rst time that this switch is pressed, the vacuum/squeegee system will NOT be turned off. This is so that any remaining water may be
picked up without having to turn the vacuum back on. If this switch is pressed a second time (pressed after the scrub system has been turned
off) the squeegee will raise and the vacuum will shut of after a 10 second delay.
•
The travel speed limit will return to the transport speed setting
•
The scrub off indicator will be green if the scrub system is off and ready to be activated. The indicator will be off if the scrub system has been
activated. If the scrub system has been turned off and the scrub deck is not up yet, or if the scrub deck is up and there is no weight on the seat,
the indicator will be red. If there is a fault in the scrub system this indicator will fl ash red.
Light Scrub Pressure Select Switch – If the scrub system is off, pressing this switch will cause the following to occur:
•
The scrub system will be enabled with the scrub pressure set to the light setting and the scrub deck will be lowered
•
The vacuum system will be enabled and the squeegee will be lowered
•
The solution system will be enabled
•
The travel speed will be limited to the scrub speed setting
•
As soon as the throttle is moved from the neutral position the scrub brushes will start turning and the vacuum will turn on. If the direction is
forward the solution fl ow will start. If the direction is reverse, the squeegee will raise and the solution fl ow will be stopped.
•
The light scrub pressure indicator will be green if the scrub system is on and the light pressure has been selected. The indicator will be off if the
scrub system is off. The indicator will be yellow if the scrub system has been enabled at the light pressure setting but the throttle is in neutral.
If the heavy scrub pressure setting is selected, pressing this switch will select the light scrub pressure. If the light scrub pressure is already selected,
pressing this switch will have no effect.
Heavy Scrub Pressure Select Switch – If the scrub system is off, pressing this switch will cause the following to occur:
•
The scrub system will be enabled with the scrub pressure set to the heavy setting and the scrub deck will be lowered
•
The vacuum system will be enabled and the squeegee will be lowered
•
The solution system will be enabled
•
The travel speed will be limited to the scrub speed setting
•
As soon as the throttle is moved from the neutral position the scrub brushes will start turning and the vacuum will turn on. If the direction is
forward the solution fl ow will start. If the direction is reverse, the squeegee will raise and the solution fl ow will be stopped.
•
The heavy scrub pressure indicator will be green if the scrub system is on and the heavy pressure has been selected. The indicator will be off
if the scrub system is off. The indicator will be yellow if the scrub system has been enabled at the heavy pressure setting but the throttle is in
neutral.
If the light scrub pressure setting is selected, pressing this switch will select the heavy scrub pressure. If the heavy scrub pressure is already
selected, pressing this switch will have no effect.
Light / Heavy Scrub Mode
Scrub System Off Switch - Pressing this switch when the scrub system is active will cause the following to occur:
•
The scrub brushes will turn off and the scrub deck will raise to the up position
• The
solution
fl ow will be stopped
• The
fi rst time that this switch is pressed, the vacuum/squeegee system will NOT be turned off. This is so that any remaining water may be
picked up without having to turn the vacuum back on. If this switch is pressed a second time (pressed after the scrub system has been turned
off) the squeegee will raise and the vacuum will shut of after a 10 second delay.
•
The travel speed limit will return to the transport speed setting
•
The scrub off indicator will be green if the scrub system is off and ready to be activated. The indicator will be off if the scrub system has been
activated. If the scrub system has been turned off and the scrub deck is not up yet, or if the scrub deck is up and there is no weight on the seat,
the indicator will be red. If there is a fault in the scrub system this indicator will fl ash red.
Light Scrub Pressure Select Switch – If the scrub system is off, pressing this switch will cause the following to occur:
•
The scrub system will be enabled with the scrub pressure set to the last used light pressure setting and the scrub deck will be lowered
•
The vacuum system will be enabled and the squeegee will be lowered
•
The solution system will be enabled
•
The travel speed will be limited to the scrub speed setting
•
As soon as the throttle is moved from the neutral position the scrub brushes will start turning and the vacuum will turn on. If the direction is
forward the solution fl ow will start. If the direction is reverse, the squeegee will raise and the solution fl ow will be stopped.
•
The light scrub pressure indicator will be green if the scrub system is on and the light pressure has been selected. The indicator will be off if the
scrub system is off. The indicator will be yellow if the scrub system has been enabled at the light pressure setting but the throttle is in neutral.
KNOW YOUR MACHINE
Содержание Adgressor BR 1050CS
Страница 74: ...72 FORM NO 56043097 Adgressor BR 850S 850CS 950S 950CS 1050S 1050CS ELECTRICAL SYSTEM Drive Motor Breakdown ...
Страница 81: ......
Страница 82: ...www nilfisk advance com 2006 ...